Clearances - Empire Comfort Systems DVL25FP32-1 Installation Instructions And Owner's Manual

Direct vent gas fireplace
Table of Contents

Advertisement

TOP VIEW
NON-COMBUSTIBLE AREA
TO SIDES AND BACK OF FIREPLACE
3"
MIN
3"
MIN
MINIMUM CLEARANCE TO PERPENDICULAR
COMBUSTIBLE SIDE-WALL
(FROM EDGE OF DOOR FRAME)
COMBUSTIBLE
FRAMING
ALLOWED
NON-COMBUSTIBLE
FINISHING
MATERIALS ONLY
12" MIN.
CLEARANCE TO
COMBUSTIBLES
REQUIRED
NON-COMBUSTIBLE
SUPPORT HEADER
RECOMMENDED
FRAMING BRACKETS
SECURE UNIT WITH
TWO SCREWS THROUGH
EACH FRAMING BRACKET
Note: Framing brackets can be attached to sides of fireplace in
one of two positions. Screw the framing brackets to the front set
of pilot holes if securing brackets over finished wal materials.
Or, attach the framing brackets to the rearward set of pilot holes
when securing unit to framed opening. See Figure 9.
Page 8

CLEARANCES

3"
MIN
6 1/2"
Figure 3
Figure 5
25" MIN.
DISTANCE FROM
TOP OF FIREPLACE
TO CEILING OR
COMBUSTIBLE MANTEL
1" MIN. CLEARANCE
FROM FRAMING TO
VENT SYSTEM
12" MIN
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
3" MIN. CLEARANCE
ABOVE VENT SYSTEM
3" MIN. CLEARANCE
TO COMBUSTIBLES
FROM BACK OF
FIREPLACE
Figure 4
29210-0-0911