Epson SL-D3000 Operation Manual page 94

Hide thumbs Also See for SL-D3000:
Table of Contents

Advertisement

D
Check the status of each head displayed in Result.
When the nozzles are cleared, "Good" is displayed.
If nozzles are clogged, a message is displayed that indicates you need to clean the Print Head Unit again.
Perform necessary cleaning.
Reading the Results:
Color
Green
Yellow
Red
White
When you want to confirm the clogged nozzles by looking at the prints, perform Print Check Pattern from Nozzle
Check (0312).
U "Nozzle Check" on page 95
Setup and Maintenance
The nozzles are not clogged.
Clogging is detected.
Perform Auto Cleaning (0311) again.
Clogging is detected.
Perform Detect Clogging from Nozzle Check (0312), and then perform Powerful
cleaning again for heads indicated by red.
Auto Cleaning is still in progress.
94