INPUT VOLTAGE(nominal)
OUTPUT VOLTAGE
OUTPUT RIPPLE & NOISE (On Full Load)
OUPUT CURRENT, CONTINUOUS
CURRENT LIMIT
COOLING
PROTECTIONS
ENVIRONMENTAL TEMP. RANGE
CONNECTIONS
AC INPUT:
DC INPUT:
FUSE RATING
DIMENSIONS ( W X D X H ), INCHES
WEIGHT
SAFETY CERTIFICATION
EMC CONFORMITY
NOTE: SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
SPECIFICATIONS
120 VAC, 60 HZ
13.8 VDC
150 mV PEAK TO PEAK
SEC-1212
10 A
SEC-1223
23A
SEC-1212
14A
SEC-1223
25A
SEC-1212 - CONVECTION COOLED
SEC-1223 - TEMPERATURE CONTROLLED FAN
OVER CURRENT, SHORT CIRCUIT AND
OVER VOLTAGE (Through PWM Controller)
OVER TEMPERATURE SHUT DOWN (SEC-1223)
SEC-1223
0 - 40
o
C
SEC-1212
0 - 30
C
o
DETACHABLE POWER CORD C/W NEMA 5-15P PLUG
TERMINALS WITH TUBULAR HOLE DIA. 0.2" (5mm)
WITH SET SCREW
5 MM X 20 MM GLASS FUSE, 125V or 250 V
(Time Delay / Slow Blow)
Bussmann
SEC-1212 - 3A
GDC-3
SEC-1223 - 6.3 A
GDC-6.3
7.0 X 8.25 X 2.2
SEC-1212
3 LBS. NET
SEC-1223
3.5 LBS. NET
UL60950-1, E179076
FCC Part 15(B), Class B Digital Device
11.

CONNECTION AND OPERATION

WARNING ! Before plugging the unit to the AC outlet, please check that
your local supply voltage is 120 VAC.
NOTE: The DC output connector (RED + & BLACK -) has a tubular hole of
dia. 0.2"(5mm) with a set screw. For a firm connection, crimp/solder a pin
type copper terminal on the cable ends of your 12V DC device.
Ensure that the power supply's ON/OFF switch is off and it is unplugged
from the AC outlet.. Switch off your 12 V DC device and connect it's
positive and negative to the RED ( Positive ) and BLACK ( Negative )
terminals respectively. Ensure that the connections are secure and tight.
Plug the power supply into the AC outlet. Press the ON/Off switch of the
power supply to ON and observe that the neon indicator in the switch
illuminates. If the indicator fails to light , recheck the connection, AC outlet
and the fuse inside the power supply.
Your 12 V DC device may now be switched on.
COOLING (SEC-1212)
SEC-1212 is cooled by convection. Operate the unit in a cool, well venti-
lated space.
COOLING AND FAN CONTROL / THERMAL SHUT DOWN (SEC-1223)
SEC-1223 is cooled by convection and forced air. A temperature controlled
fan has been provided to improve cooling at higher loads. The fan is
Littelfuse
controlled by a sensor mounted on the power transformer. THE FAN WILL
239003
BE OFF AT LOWER LOADS. It will come on only when the temperature
21806.3
of the power transformer is above 70ºC due to higher loads. In case the fan
fails or the air flow is blocked, a second temperature sensor mounted on
the power transformer will activate over temperature shut down at 100ºC.
The output voltage will be automatically resumed once the unit cools down.
OPERATE THE UNIT IN A WELL VENTILATED OPEN AND COOL AREA.
DO NOT BLOCK THE OPENINGS AT THE FAN DISCHARGE ON THE
BOTTOM AND THE SUCTION OPENINGS ON THE SIDES .
4.