Page 1
OWNER'S MANUAL ________________ DS73 & DS73TP ETHERNET PERIPHERAL COMMUNICATIONS MODULE FOR THE DS-DATA SWITCH BayTech Manual Publication #U140A126...
Page 2
Thank you for selecting a DS73 or DS73TP Ethernet Peripheral Communications Module for the DS Data Switch. The data provided in this Owner's Manual explains the various ways you can operate your DS73/DS73TP Peripheral Communications Module and configure it to your own computer system.
Page 3
NOTE: The information contained in this document is subject to change without notice. Copyright 1997 by Bay Technical Associates, Inc. BayTech, Telplex, LaserShare, Print Master and TRAN-X are registered trademarks of Bay Technical Associates, Inc. IBM, IBM PC, IBM PC/AT, IBM PC/XT are products and registered trademarks of International Business Machines Corporation.
4.1.4 SELECT CODE...8 4.1.5 PASSWORD...8 4.1.6 USER INTERFACE ...Error! Bookmark not defined. 4.2 DS73 PERIPHERAL CONNECTION...Error! Bookmark not defined. 4.3 REVERSE TELNET OPERATION ...Error! Bookmark not defined. 4.4 RESOURCE RELEASE FUNCTION...Error! Bookmark not defined. 5 USER INTERFACE...Error! Bookmark not defined.
Page 5
8 DS73 & DS73TP CONFIGURATION...Error! Bookmark not defined. 8.1 MAIN CONFIGURATION MENU...Error! Bookmark not defined. 8.2 IP ADDRESS...9 8.3 SUBNET MASK...10 8.4 GATEWAY...10 8.5 SELECT CODE...Error! Bookmark not defined. 8.6 PASSWORD ...10 8.7 DS73/DS73TP USER INTERFACE...Error! Bookmark not defined. 8.7.1 ID MSG: MODULE ID MESSAGE...Error! Bookmark not defined.
DS-Series data switch. Use the DS73 module for in-band network management. And use the DS74, EIA-232 module for out-of-band management. Remote workstations and PCs connect to the DS73 using a dial-up PPP session. This offers dial-up users a low cost IP network link suitable for remote access to the network.
SUBNET MASK The SUBNET Mask is a bit mask that identifies the network portion of the IP address, allowing the DS73 to determine whether to send a packet directly to the client or to a gateway. The Subnet Mask consists of four bytes with each byte ranging from 0 to 255 decimal.
USER NAME The DS73 User name is required of all users who attempt to access the DS73. The user name is given by the user when establishing a connection to the DS 73 module. The user name consists of an ASCII character string with a maximum length of 8 characters.
By responding to the Enter Request: message at the end of the configuration menu with “2” you receive the configuration menu for Module 2 that looks similar to the following: DS73 Ethernet Module F 0.02 Copyright (c) 1997 Bay Technical Associates...
IMPORTANT: After programming the Gateway address, the unit must be reset for the new information to take effect. Primary DNS Type “5”(Primary DNS) at the end of the main configuration menu and you can program the Primary DNS. The DS73 will respond with:...
Accept password as typed above? (Y/N) : Press "Y" to accept the new password or "N" to reject it. If you press "N", the DS73 will return to the "Enter Password" prompt. If you type "Y", the DS73 will return to the main configuration menu.
By responding to the Enter Request: message in the DS73 Status & Diagnostics Menu with “X” (Exit), you will exit the DS73 Status & Diagnostics Menu. The DS73 peripheral module will respond with the following: > X 5.1.6 LOGOUT By responding to the Enter Request: message in the DS73 Main Menu with “T” (Logout), you will terminate your TELNET connection.
GETTING STARTED Before the DS73 or DS73TP and the DAC can be used, there are a few parameters which must be configured by the user. First time power-up: When the DS73 or DS73TP is first powered up, it will cycle through its diagnostics until it finds that it has not been programmed with an IP address or subnet mask.
RETURNS TO THE FACTORY If you find it necessary to return any component of the DS-Seriesunit to the factory for warranty work or factory-set changes, follow the procedure listed under Section 12 for repackaging. Before you ship your unit, please call BayTech to get a Return Authorization number.
DS73-A or DS73TP-A. d. Be careful not to bend any of the pins. Insure that none of the pins miss the receptacles of the sockets. Re-install the DS73 and apply power to the unit. The upgrade is now complete. Before you operations, check the configuration status to make certain it matches your application.