Electrical Specifications - Amprobe PM51A User Manual

Pocket multimeter
Hide thumbs Also See for PM51A:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Special Features
Data Hold, and 30ms MAX Hold
Agency Approvals
P >
Safety: Meets IEC61010-1, UL61010B-1, CAN/CSA-C22.2 No. 1010.1-92,
CAT II 600 V and CAT III 300 V, Pollution Degree 2, Class 2
E.M.C. Meets EN61326 (1997, 1998/A1), EN61000- 4-2 (1995), and EN61000-4-3 (1996). This
product complies with requirements of the following European Community Directives: 89/ 336/ EEC
(Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE
Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment
may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals
that may be present within the measurement circuit. Users should exercise care and take appropriate
precautions to avoid misleading results when making measurements in the presence of electronic
interference.
Accessories
Battery installed, and User's manual
Optional Accessories:
H-PM protective holster, and VC3 soft carrying pouch

Electrical Specifications

C ± 5
o
(Accuracy @ 23
RF Field @ 3 V/m: Specified accuracy + 45 d (Capacitance not specified)
DC Voltage
400.0 mV
4.000 V, 40.00 V, 400.0 V
600 V
NMRR: > 50 dB @ 50 Hz/60 Hz
CMRR: > 120 dB @ dc, 50 Hz/60 Hz; Rs=1 kΩ
Input Impedance: 10 MΩ, 30 pF nominal; (1000 MΩ for 400.0 mV range)
o
C and < 75% R.H.)
Range
9
Accuracy
±(1.0%+2 dgt)
±(2.0%+2 dgt)
±(2.5%+4 dgt)