Electrical Specifications - Amprobe ACD-14-PRO User Manual

Dual display 600 a trms clamp multimeters
Table of Contents

Advertisement

Available languages

Available languages

ELECTRICAL SPECIFICATIONS

Accuracy is ± (% reading digits + number of digits) or otherwise specified at
23°C ± 5°C.
Maximum Crest Factor < 2.5:1 at full scale and < 5:1 at half scale or
otherwise specified, and with frequency spectrum not exceeding the
specified frequency bandwidth for non-sinusoidal waveforms.
DC Voltage
Range
600.0V
Input Impedance: 10 MΩ, 100 pF nominal
AC Voltage
(with Digital Low-Pass Filter)
Range
600.0V
Frequency: 50 Hz to 60 Hz
Input Impedance: 10 MΩ, 100 pF nominal
Continuity
Audible Threshold: ON at ≤ 10 Ω ; OFF at > 250 Ω
Response time: 32ms approx.
Resistance
Range
600.0 Ω, 6.000 kΩ, 60.00 kΩ
1)
600.0 kΩ
, 6000 kΩ
Open Circuit Voltage: 1.7VDC typical
1) Test Current: 2 μA typical
2) Test Current: 0.2 μA typical
Capacitance
Range
200.0 μF, 2500 μF
1)Accuracy with film capacitor or better
Diode
Range
3.000 V
Test Current: 0.3mA typically
Open Circuit Voltage: < 3.5 V DC typical
Accuracy
± (1.0 % + 5 LSD)
Accuracy
± (1.0 % + 5 LSD)
Accuracy
± (1.0 % + 5 LSD)
2)
± (1.2 % + 5 LSD)
Accuracy
± (2.0 % + 4 LSD)
Accuracy
± (1.5 % + 5 LSD)
1)
14

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Acd-14-pro-eur

Table of Contents