Installation Size; Specifications - Emerson EV3200 User Manual

Door control inverter
Table of Contents

Advertisement

4
Chapter 2 Product Specifications

2.4 Installation Size

Inverter model
EV3200-2S0002A
EV3200-2S0002S
EV3200-2S0004A
EV3200-2S0004S

2.5 Specifications

Items
Subitems
Voltage range
Input
Frequency range
Voltage range
Output
Frequency range
Overload ability
Load motor type
Modulation mode
Control algorithm
Operation mode
Frequency
resolution
Main control
functions
Door width auto
learning
Auto tuning of
motor's
parameters
Speed-adjusting
range
OD, CDcontrol
command input
Frequency setting
Operation
Multi-function
functions
terminal input
signal
Output signal
Display
4-digit LED display
Table 2-1 Inverter external size and installation size
Installation size
A (mm)
B (mm)
289
172.5
Single-phase AC power, 180V ~ 264V
50Hz ± 5%, 60Hz ± 5%
Three-phase: 0V ~ input voltage
0Hz ~ 128Hz
150% rated current for 1 minute, 180% rated current for 10 seconds
Three-phase AC asynchronous motor, three-phase AC synchronous motor
Optimized space voltage vector PWM modulation
Sensorless vector control, vector control with speed sensor
Two modes: 1. The inverter operates as an inverter specially used for controlling the elevator door
(elevator door control mode), 2. The inverter operates as a general purpose inverter
Digital setting: 0.01Hz
The inverter operates at the auto-learnt speed, and operates in the logic procedure of close door (CD)
→open door (OD)→CD→stop. After the auto-learning operation, the door width information is saved
and the auto learning process is over
Purpose of auto tuning function of inverter is to obtain the motor's parameters automatically, and these
parameters will be saved automatically after the tuning process is over
Under rated load condition, 1:100 for vector control with speed sensor; 1:50 for sensorless vector
control
Terminal control mode; keypad control mode; communication control mode (reserved)
Set the frequency via keypad; communication control mode (reserved)
External reset signal, light curtain signal, safety edge signal, OD position limiting signal, CD position
limiting signal, OD speed decrease signal, CD speed decrease signal, OD prohibition signal, torque
maintaining signal, slow OD and CD signals, lock signal, emergency firemen service (EFS) signal, rush
hour operation enable operation, operation enable signal, auto-learning command signal
3 relay-output: 250Vac/2A (cosΦ=1), 250Vac/1A (cosΦ=0.4), 30Vdc/1A
Running frequency, reference frequency, output voltage, output current, output torque, DC bus voltage,
status of input terminals, status of output terminals, door-operating position (pulse number)
EV3200 Door Control Inverter User Manual
External size
L (mm)
W (mm)
H (mm)
298
190
Specifications
Installation hole
Weight (kg)
diameter (mm)
60
Φ4
0.9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents