8
Chapter 3 Electrical Installation

3.2 Control Terminals

A
Terminal
User terminal 24V power supply (COM being the
P24, COM
reference earth)
A, B
AB pulse input terminal of incremental PG
Multi-function input terminals (functions programmable,
X1 ~ X5
COM being the reference earth), or Z pulse input
terminal of incremental PG
OD
OD command input terminal
CD
CD command input terminal
Note
If the control cables are multi-core cables, it is recommended that the sectional area of a single strand of the control cables be 0.5mm
the control cables are single-core cables, the cable sectional area should be greater than 1.0mm

3.3 User Relay Output Terminals

A
Terminal
PA1, PC1
PA2, PC2
PA3, PB3, PC3
EV3200
Figure 3-3 Control terminals
Table 3-4 Function description of control terminals
Terminal function
Figure 3-4 User relay output terminals
Table 3-5 Function description of user relay output terminals
Terminal function
When F9.22 is 0: normally closed contact output
When F9.22 is 1: normally open contact output
When F9.22 is 0: normally closed contact output
When F9.22 is 1: normally open contact output
PA3, PB3: Normally closed contact output
PA3, PC3: Normally open contact output
EV3200 Door Control Inverter User Manual
P24
COM
A
B
+24V ± 15%, max output current: 200mA, with output
shortcircuit protection function
Meeting the input requirements of pulse signal with frequency
below 35kHz
Terminal command valid when shorted with COM
2
.
EV3200
PA1 PC1
Contact rating
AC: 250V/1A (cosΦ=0.4), 250V/2A (cosΦ=1)
DC: 30V/1A
X1
X2
X3
X4
X5
COM
OD
CD
A amplified view
Specifications
PA2
PC2
PA3
PB3
PC3
A amplified view
Specifications
2
. If