18
Chapter 5 Parameter Table

5.6 Multi-function Input Terminal Parameters F5

Parameter
F5.00
F5.01
Function selection for
F5.02
control terminals X1 ~ X5
F5.03
F5.04
Function of programmable
F5.05
relay output PA1/PC1
Function of programmable
F5.06
relay output PA2/PC2
Function of programmable
F5.07
relay output PA3/PB3/PC3

5.7 Motor Parameters F6

Parameter
F6.00
Motor type selection
F6.01
Motor rated power
F6.02
Motor rated voltage
F6.03
Motor rated current
Motor max allowable operation
F6.04
current
F6.05
Motor rated frequency
F6.06
Motor rated spinning speed
Name
0: No functions (can be set repetitively)
1: External reset (RESET) signal input
2: Normally open input contacts for light curtain signal
3: Normally closed input contacts for light curtain signal
4: Normally open input contacts for safety edge
5: Normally closed input contacts for safety edge
6: Normally open input for OD position limiting
7: Normally closed input for OD position limiting
8: Normally open input for CD position limiting
9: Normally closed input for CD position limiting
10: Normally open input contacts for OD speed decrease
11: Normally closed input contacts for OD speed decrease
12: Normally open input contacts for CD speed decrease
13: Normally closd input contacts for CD speed decrease
14: Terminal for inputting OD prohibition signal
15: Terminal for inputting torque maintaining prohibition signal
16: Low speed OD/CD enable signal input
17: Normally open input for lock signal
18: Normally closed input for lock signal
19: Emergency Firemen Service (EFS) function input
20: Rush hour operation enable signal input
21: Operation enable signal input (valid for X5 only)
22: Door width auto-learning command input (valid for X5 only)
0: Output signal 0 for complete OD
(immediately output upon position limiting)
1: Output signal 0 for complete CD
(immediately output upon position limiting)
2: Output signal 1 for complete OD
(output after position limiting and lock)
3: Output signal 1 for complete CD
(output after position limiting and lock)
4: Output signal 2 for complete OD
(output after position limiting, lock, and door lock invalid)
5: Output signal 2 for complete CD
(output after position limiting, lock, and door lock valid)
6: Fault relay output 1
(not including POFF status)
7: Fault relay output 2
(including POFF status)
8: Safety edge lift signal output
9: Lock signal synchronous output
10: Re-opening signal output
11: Obstruction signal output
Name
0: asynchronous motor;
1: synchronous motor
0 ~ 500W
0 ~ 250V
0.10 ~ 9.90A
100.0% ~ 200.0% (motor rated current)
1.00Hz ~ 128.0Hz
1 ~ 9999rpm
EV3200 Door Control Inverter User Manual
Setting range
Setting range
Min. unit
1
1
Min. unit
Default
1
0
1W
370
1V
220
0.01A
1.94
0.1%
150.0%
0.01Hz
50.00Hz
1r/min
1400
Default Mod.
0
×
2
3
×
6
Mod.
×
×
×
×
×
×
×