7.4 Distance Control 2

In this mode, refer to Figure 7-3 for the system configuration, the PG may not be connected to the motor shaft.
For distance control 2 mode, except that F0.01 should be set to 2 (distance control 2), all parameter settings are the same as
those for distance control 1 mode. Refer to the testing procedures of distance control 1 mode for the testing procedures of
distance control 2 mode.

7.5 Distance Control 3

7.5.1 System Wiring Diagram

Single phase
power supply
50/60Hz

7.5.2 Testing Procedures

1. Do the wiring according to Figure 7-5.
2. Switch on the inverter, set F9.18 to 2 to restore the factory settings.
3. Carry out motor tuning according to instructions provided in 7.1 Motor Type Setup. The parameters will be saved
automatically after tuning.
4. Set F0.01 to 3, set F4.01 and F4.02 (0: forward, 1: reverse) correctly. After exiting the programming status, press
to start the operation in keypad control mode, and adjust F4.02 setting according to the actual operating conditions. If over
current or over load occurs, or the output current exceeds the motor rated current, adjust the setting of F4.02 to ensure correct
PG parameter settings, and restart the inverter.
5. Switch off the inverter, connect the elevator door mechanical system and switch on the inverter again.
6. Set F0.02 to 1 (keypad control mode), select auto-learning speed properly via F4.04, set F4.05 to 1, press
door-width auto learning, and the motor operates according to the procedures of CD→OD→CD. The inverter stops after the
last motor catching. The door width information will be saved automatically after auto-learning.
Note
If the actual operation direction is reverse to OD/CD command, change the setting of F0.03 to 1, and change the setting of F4.02
accordingly.
MCCB
L
N
Light curtain NO input
X1
Safety edge NO input
X2
OD position
limiting NO input
X3
CD position
limiting NO input
X4
COM
OD command input
OD
CD command input
CD
Figure 7-5 System wiring diagram for distance control 3(asynchronous motor)
EV3200 Door Control Inverter User Manual
EV3200 inverter
P24
COM
A
B
PA3
PB3
PC3
PA1
PC1
PA2
PC2
Chapter 7 Application Guidance
U
V
M
W
PE
PG
PG: pulse generator
Fault relay
Complete OD
relay output
Complete CD
relay output
43
(or
)
to start