3 Monitoring the running status -- Menu #3 "Drive Monitoring" --
Listed below are monitoring items added or modified in the FRENIC-MEGA series of inverters having a ROM version
3000 or later.
LED
monitor
shows:
Target position pulse
3_17
(synchronous operation)
Current position pulse
3_18
(synchronous operation)
Current deviation pulse
3_19
(synchronous operation)
Control status monitor
3_20
(synchronous operation)
Positioning deviation
3_26
(synchronous operation)
Item
Unit
Pulse
Pulse
Pulse
--
degree
Description
Shows the target position pulse for synchronous
operation.
Shows the current position pulse for synchronous
operation.
Shows the current deviation pulse for synchronous
operation.
Shows the current control status.
0: Synchronous operation disabled
20: Synchronous operation canceled
21: Synchronous operation stopped
22: Waiting for detection of Z phase
23: Z phase of reference PG detected
24: Z phase of slave PG detected
25: Synchronization in progress
26: Synchronization completed
Shows the positioning deviation (in degree) for
synchronous operation.