Noise Cancel Test; Audio Reset Test; Earset Test - Minelab F1A4 Service Manual

Metal mine detector
Hide thumbs Also See for F1A4:
Table of Contents

Advertisement

4.5

NOISE CANCEL TEST

Momentarily press the NOISE CANCEL button.
The F1A4 should immediately "beep"
After 70 seconds the F1A4 should "beep" four times:
BEEP BEEP BEEP BEEP
If the correct tones are not heard, go to Section 5.1.4
4.6

AUDIO RESET TEST

Momentarily press the AUDIO RESET button.
The F1A4 should immediately BEEP.
After 3 seconds the F1A4 should give five "high / low" beeps:
BEEP
The threshold tone level should now be set at the correct operating level (ie
just audible). If the correct tones or threshold level are not heard, go to Section
5.1.5
4.7

EARSET TEST

Connect the Earset to the Control Box and ensure that the threshold tone is
audible at the earphone. If a volume control is fitted, ensure that it operates
correctly. If the Earset does not operate correctly, go to Section 5.1.6.
F1A4 Field Service Manual – Level 1 and Level 2 Maintenance
BEEP
BEEP
BEEP
Page 19
BEEP

Hide quick links: