5. Press the MENU/ESC key twice to close
the window.
MANUAL L:2.0/H:2.0 LF
Weak reflection
(small fish or noise)
Fish echo
Strong reflection
(bottom)
46.1
ft
Single frequency display
"Peak" show past amplitude with dots.
1.16

Alarms

The FCV-1150 has six conditions which gen-
erate both audio and visual alarms: bottom
alarm, normal fish alarm, bottom lock fish
alarm, water temperature alarm, speed alarm
and arrival alarm. (The water temperature,
speed and arrival alarms require appropriate
sensors.) When an alarm is violated the audio
and visual alarms are released. You can si-
lence the buzzer with any key. The visual
alarm (icon) remains on the screen until the
cause of the alarm is removed or the alarm is
disabled.
MANUAL L:2.0/H:2.0 LF
An alarm icon
appears when
an alarm has
F
been violated.
Bottom alarm: The bottom alarm alerts you
when the bottom (displayed in red or reddish
brown echo) is within the alarm range set. To
activate the bottom alarm the depth must be
displayed.
1/2
0
20
40
60
A-scope
display
Alarm icon
(flashing)
1/2
: Bottom alarm
: Fish alarm (specific area)
: Fish alarm (all areas)
: Fish alarm (bottom lock)
: Temperature alarm (°F)
: Speed alarm
: Arrival alarm
Fish (normal) alarm: The fish (normal) alarm
tells you when an echo above a certain
strength (selectable) is within the preset alarm
range or an echo of yellow color or stronger
color is anywhere between the transducer
and the bottom.
Fish (bottom lock) alarm: The fish (bottom
lock) alarm sounds when fish are within a cer-
tain distance from the bottom. Note that the
bottom lock and bottom discrimination (1/2 or
1/3) displays must be turned on to use this
alarm.
Water temperature alarm: The water tem-
perature alarm alerts you when the water tem-
perature is within (inside alarm) the alarm
range set or under/over (outside alarm) the
range set.
Speed alarm: The speed alarm alerts you
when the speed is within (inside alarm) or un-
der/over (outside alarm) the preset speed.
Arrival alarm: The "Inside" arrival alarm
alerts you when you approach to the destina-
tion waypoint by the distance set. Alternative-
ly, the "Outside" arrival alarm alerts when
your vessel travels a specific distance from
the destination waypoint.
Activating an alarm
1. Press the MENU/ESC key to open the
menu.
2. Use
or
to select Alarm and press the
ENTER key.
*
*
*
*
*
*
*: Value not adjustable when
alarm is inactive.
13
1. OPERATION

Hide quick links: