Event Identifier - Honeywell ADEMCO LYNXRIEN-EA User Manual

Table of Contents

Advertisement

USER FUNCTIONS
Scheduling User Interface
NOTE: The keypad beeps twice for invalid data entries (e.g.: an hour greater than 12), and the entry will not be
accepted. The keypad beeps once for valid entries and four times when a schedule event is programmed
successfully.
[x] = the value that was last stored in the memory.
Schedule number
x
n
[x] = schedule number 1 to 8
[*] = continue
[#] = exit schedule programming
mode

Event Identifier

x
id
[x] = event identifier 0 to 5
[*] = continue
[#] = return to previous prompt
Begin Time (hour)
xx : Ab
[xx] = begin hour 00 to 12
[*] = continue
[#] = return to previous prompt
Begin Time (am/pm)
[0] = begin time, am (A)
[1] = begin time, pm (P)
[*] = continue
[#] = return to previous prompt
Enter the 1-digit schedule number to be programmed, then
press [*] to accept and advance to the next programming field:
Event Identifier.
Press the [#] key in this entry will exit the schedule
programming mode. The keypad will beep four times and
exit.
• Schedule number 7 and 8 are always random events that
are meant to work only with X10 devices.
NOTE: This feature should be implemented when the user is
trying to give the impression that a premises is "lived in".
The events will occur at random times (0-59 minutes)
within the defined hour.
0 = Empty - no event scheduled (or schedule temporarily
disabled. Keypad will beep four times and return to
Schedule Number with the schedule number advanced.
1 = X10 Device - the user is required to enter data up to and
include the Device Number screen. Selection #1 is a time
driven event that requires a begin and end time.
2 = Latch Key Report - the user is required to enter data up
to and include the End Day screen. Selection #2 is a window
driven event that requires a begin/end time.
3 = Automatic Stay Arming - the user is required to enter
data up to and include the Begin Day screen. Selection #3 is
a time driven event that requires a begin time to send a
report.
4 = Reminder Announcements - the user is required to enter
data up to and include the Begin Day screen. This is a
reminder announcement.
5 = Alarm Clock - the user is required to enter the field
values up to and include the Begin Day screen. This is a an
alarm clock.
NOTES: (1) See figure 1 for an explanation of each entry of the
event identifier.
(2) If "Follow me" reminder telephone number is
programmed, the reminder announcement is also
delivered to that number.
The begin hour is a two-digit entry. To enter the hour 3,
press "0" followed by "3".
The begin hour "00" indicates this schedule does not have
a begin time.
Press "0" to select AM or "1" to select PM.
NOTE: When programming schedule number 7 and 8, do not
program turn on/off to occur within the same 1-hour
period. This will prevent this random feature from
causing a reversal of the on/off times.