Functional Description; Carton Contents - Delta 36-850 Instruction Manual

Stock feeder
Table of Contents

Advertisement

EXTENSION CORDS
Use proper extension cords. Make sure
your extension cord is in good condition and is a 3-wire
extension cord which has a 3-prong grounding type
plug and matching receptacle which will accept the
machine's plug. When using an extension cord, be sure
to use one heavy enough to carry the current of the
machine. An undersized cord will cause a drop in line
voltage, resulting in loss of power and overheating. Fig.
D-1 shows the correct gauge to use depending on the
cord length. If in doubt, use the next heavier gauge. The
smaller the gauge number, the heavier the cord.
FOREWORD
The Delta Model 36-850 four-speed, three-roller, Stock Feeder includes a 1/4 hp, 120V single-phase reversing motor, 3
rubber feed rollers, vertical and horizontal support columns, universal joints, and an additional set of speed-changing
gears and lubricating gun.
NOTICE: The photo on the manual cover illustrates the current production model. All other illustrations contained in
the manual are representative only and may not depict the actual color, labeling, or accessories and are intended to
illustrate technique only.
1) Stock Feeder Assembly
2) Vertical and horizontal Support Columns
UNPACKING AND CLEANING
Carefully unpack the machine and all loose items from the shipping container(s). Remove the protective coating from
all unpainted surfaces. This coating may be removed with a soft cloth moistened with kerosene (do not use acetone, gaso-
line or lacquer thinner for this purpose). After cleaning, cover the unpainted surfaces with a good quality household floor
paste wax.

FUNCTIONAL DESCRIPTION

CARTON CONTENTS

MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere
Rating
Volts
0-6
120
0-6
120
0-6
120
0-6
120
6-10
120
6-10
120
6-10
120
6-10
120
10-12
120
10-12
120
10-12
120
10-12
120
12-16
120
12-16
120
12-16
120
3) Additional Set of speed-changing gears
4) Lubricating Gun
7
Total Length
Gauge of
of Cord in Feet
Extension Cord
up to 25
18 AWG
25-50
16 AWG
50-100
16 AWG
100-150
14 AWG
up to 25
18 AWG
25-50
16 AWG
50-100
14 AWG
100-150
12 AWG
up to 25
16 AWG
25-50
16 AWG
50-100
14 AWG
100-150
12 AWG
up to 25
14 AWG
25-50
12 AWG
GREATER THAN 50 FEET NOT RECOMMENDED
Fig. D-1

Hide quick links:

Advertisement

Table of Contents
loading