4. Cut (#1) wire (as shown), and connect the ignition switch side of the cut wire to terminal #87a of the
relay. Connect the other side of the (#1) wire to terminal #30.
5. Connect the previously selected resistor from terminal #87 to the second (#2) wire (as shown).
NOTE: The above information and following diagram is for the GM VATS system only.
D. Anti-Grind Starter Circuit Connection:
This wire, when connected to a starter inhibit relay, as shown in the diagram below, will prevent the
customer from engaging the starter while the vehicle is running under control of the remote start.
Configured in this way, while the remote start is controlling the vehicle, the light blue wire has ground on
it all the time. This ground will cause the relay to energize preventing current flow through the normally
closed contacts. This will prevent a customer who inadvertently turns the ignition switch to the start
position, from sending current to the starter.
4 Dark Green Wire: (-) Instant Trigger Input
The Dark Green wire is the instant on ground trigger input wire. This wire must be connected to the hood pin
switch previously installed, and the trunk pin switch where used.
NOTE: This wire will be shunted when remote control channel 3 is accessed, (trunk release). This wire will
remain shunted all the while there is ground present and for 5 seconds after the ground is removed.
This allows the operator to open the trunk via the remote transmitter without having to first disarm
the alarm system.
5 Dark Blue/Black Trace Wire: External Trigger Input
The Dark Blue/Black trace wire allows the remote start unit to be activated from an external source. The
intent of this wire is to allow the unit to be controlled from a "POSSE/CAR-LINK" paging system or similar
device. When this wire receives a ground pulse, the unit will start the vehicle. Connect this wire to a ground
pulsed output from the controlling circuit.