MAINTENANCE

When adhesives from the film build up on the rollers the quality of lamination
will decrease and jamming may occur. Please clean the rollers regularly.
1. Turn on the laminator and set the temperature at 100°C(212°F) and set the mil
thickness at 100 mic(4mil).
2. Insert a sheet of clean thick paper (about 0.5 mm or 1/50" thick) into the front
opening of the machine 2-3 times to remove excess adhesive from the rollers.
3. To thoroughly clean the rollers make sure the machine is in the COLD mode and the
rollers are completely cool.
4. Unscrew the 2 screws on the cover using a screwdriver. Once the screws are off,
remove the top cover.
5. Use a cleaning solvent such as Laminex Poly-Off or something equivalent on a lint
free cloth to clean residue on the rollers. (Do not use alcohol or petroleum based
cleaning solvents or abrasives.)
6. Place the cover back on and screw in tightly.
7. Use and store this unit in a dry area, damp areas may damage the machine.

TROUBLESHOOTING

Problem
Motor doesn't work
Pouches are not
laminating correctly
Possible Cause
- Power cord may not be
plugged in.
- Power switch is off
- If laminating heat sealed
pouches, the machine may
be set in the COLD mode
- The temperature may be
set too low.
- The speed is set too high
10
NPH-1200N/900N
Possible Solution
- Check and plug in the
power cord.
- Check and turn on the
power.
- Make sure the machine is
in the HOT mode
- Check the temperature is
set according to pouch
thickness.
- Adjust to a lower speed.