INITIAL STAR T-UP FOR THE
DIPLOMA T, CHAIRMAN, CALI -
FORNIAN, NA UTILUS, A URORA I
AND AURORA II
1) Before filling your spa, install the black plastic hose bib that is
included in the owner's manual packet located in the equipment com-
partment. Screw it onto the male fitting at the bottom of the spa on
the pedestal, to the lower left of the equipment compartment. Close
the valve and screw the cap onto the end of the bib. Check the pump
unions to be sure that they are tight to prevent the possibility of leak-
age in the equipment compartment. Also, open both bleeder valves
located in the skimmer area.
2) Fill your spa with water to a level of one to two inches above the bot-
tom of the tile line.
3) Turn on the circuit breaker. After a 5 second diagnostic check, the
ozone generator and circulation pump will come on. Similarly, the
"SET CLOCK" message will be indicated on the upper line of the
LCD display. If you do not set the proper time, the system will
default to 11:59 A.M.. For more information about programming
functions, please see page 30. One minute after the system power is
first initiated, the internal time clock is automatically set to initiate
the first filtration cycle. The filtration system factory default is two,
one hour cycles.
4) Push the JETS 2 pad to prime the second pump. Let the system run
for 30 to 45 seconds to prime the pumps. If there is no jet action,
then the water level is too low or there is air trapped in the plumbing
lines. To eliminate the trapped air, turn the pumps on and off several
times to force the trapped air through the pumps. If there is still no
jet action, and the bleeder valves have been open for some time, turn
off the pumps and loosen the top pump unions slightly to let any
trapped air escape. Re-tighten the pump unions and turn the on the
pumps again. Turn the pumps on and off several times until jets func-
tion properly.
NOTE: Bubbles will continue to release from the skimmer recess Ultra
Pure bleeder valve as long as the valve remains open. This is a normal
function.
1998 Owner's Manual