ELECTRICAL REQUIREMENT CHART
Electrical
Model
Rating
D i p l o m a t
2 4 0 V, 32A 3 Wire + ground
2 4 0 V, 24A 3 Wire + ground
C h a i r m a n
2 4 0 V, 32A 3 Wire + ground
2 4 0 V, 24A 3 Wire + ground
C a l i f o r n i a n 2 4 0 V, 32A 3 Wire + ground
2 4 0 V, 24A 3 Wire + ground
N a u t i l u s
2 4 0 V, 32A 3 Wire + ground
2 4 0 V, 24A 3 Wire + ground
Aurora I
2 4 0 V, 24A 3 Wire + ground
Aurora II
2 4 0 V, 32A 3 Wire + ground
2 4 0 V, 24A 3 Wire + ground
I n t e r l u d e
2 4 0 V, 24A 3 Wire + ground
A r e n a
2 4 0 V, 24A 3 Wire + ground
Tr i a d
2 4 0 V, 24A 3 Wire + ground
Q u a d r a
2 4 0 V, 29A 3 Wire + ground
2 4 0 V, 24A 3 Wire + ground
1 2 0 V, 12A 2 Wire + ground
To hook-up your spa, follow these instructions:
1) Remove the screws holding the ventilated equipment access panel to
the front of the spa cabinet and set the panel aside.
2) Loosen the four screws located on the front of the black equipment
control can and remove the door from the control can to allow access
to the four wire connection terminal block.
3) Attach 1" rigid non-metallic conduit to the conduit nipple located in
the pedestal base on the side of the spa and run required conductors
through the conduit to the equipment can.
4) Connect the four wires to the equipment system terminal block (TB1)
as indicated on the wiring diagram in the back of this manual.
Replace the door on the control can and re-tighten the securing
screws.
Branch Cir.
Branch Cir.
Protection
4 0 A
3 0 A
4 0 A
3 0 A
4 0 A
3 0 A
4 0 A
3 0 A
3 0 A
4 0 A
3 0 A
3 0 A
3 0 A
3 0 A
4 0 A
3 0 A
1 5 A
1998 Owner's Manual
Gauge
#6 AW G
#8 AW G
#6 AW G
#8 AW G
#6 AW G
#8 AW G
#6 AW G
#8 AW G
#8 AW G
#6 AW G
#8 AW G
#8 AW G
#8 AW G
#8 AW G
#6 AW G
#8 AW G
#12 AW G
16