Heater And Circulation Pump Control - Dimension One Spas 1998 Owner's Manual

Dimension one spas 1998
Table of Contents

Advertisement

13
1998 Owner's Manual
chemistry such as pH and total alkalinity must adhere to the manufactur-
er's instructions relative to that specific product. As Dimension One
Spas has no control over the water source used in any spa application, it
will not be responsible for any staining below the water line and any such
occurrence will not be covered under any of its warranties.

HEATER AND CIRCULATION PUMP CONTROL

On all Dimension One Spas, when the water temperature is 1˚ below the
set temperature the heater will turn on and remain on until the water tem-
perature rises to 1˚ above the set temperature. On models that do not
have circulation pumps (Interlude, Arena, Triad and Quadra without the
CrystalZone Water Management System) the low speed pump will turn
on during the heating cycle.
On models with Ultra Pure (Chairman, Diplomat, Californian, Nautilus,
Aurora II and Aurora I) and models with the Crystal Zone Water
Management System: To prevent the spa from overheating, the circula-
tion pump turns off when the water temperature rises 2˚ above the set
temperature. When the water temperature cools down to the set tempera-
ture, the circulation pump will turn on.
NOTE: The circulation pump will run for short periods when the water
temperature is 2˚ above set temperature to provide optimum operation.
BEFORE ATTEMPTING TO HOOK-UP OR USE YOUR SPA,
PLEASE READ THROUGH THESE INSTRUCTIONS AND CARE-
FULLY VIEW YOUR OWNER'S MANUAL VIDEO.

Advertisement

Table of Contents
loading

Table of Contents