Location Requirements - Whirlpool 29" Wide Models Installation Instructions Manual

Electric dryer
Hide thumbs Also See for 29" Wide Models:
Table of Contents

Advertisement

Location Requirements

You will need:
A location allowing for proper exhaust installation.
See "Venting Requirements."
A separate 30 amp circuit.
If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
A sturdy floor to support the total weight (dryer and load)
of 200 lbs. (90.7 kg). The combined weight of a companion
appliance should also be considered.
Level floor with maximum slope of 1" (25 mm) under entire
dryer. (If slope is greater than 1" [25 mm], install Extended
Dryer Feet Kit, Part Number 279810.) If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation clearances:
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
Front View
29"
(737 mm)
NOTE: Leveling legs should be 1/2" (13 mm) (to match height
of 3.6 cu. ft. capacity washer) or 1½" (38 mm) (to match height
of 3.8 cu. ft. capacity washer).
43
/
"
3
8
(1102 mm)
/
"
1
2
(13 mm)
Side View
22
/
"
27
"
/
3
3
4
4
(578 mm)
(705 mm)
A
A. Wide opening side-swing door
B. Wide opening hamper door
*Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Back View
4"
(101 mm)
4
"
14
"
/
/
3
1
4
2
(121 mm)
(368 mm)
Steam
Minimum spacing for recessed area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
Companion appliance spacing should also be considered.
27
13
/
"
3
3
4
(349 mm)
(705 mm)
B
30
/
"
1
4
(768 mm)
4
"
14
/
/
3
1
4
(121 mm)
(368 mm)
Non-Steam
"
/
4
"
2
5

Hide quick links: