Tools And Materials Needed For Installation; Gas Supply Requirements - Whirlpool Gas Dryer Installation Instructions

Gas dryer

Advertisement

Before you start...
Important:
Observe
all
governing
codes
and
ordinances.
Check location
where dryer will be
installed.
Proper installation
Is your
responsibility.
The dryer must not
be installed
or stored in an area
where it will be exposed
to water
and/or
weather.
Make sure you
have everything
necessary
for
conect
installation.
Proper gas and electric
supply connections
should
be available.
Protectlon from the weather:
Proper operation
of dryer
cycles requires temperatures
above
45°F.. or the dryer
may not shut off when
automatic
cycles are used.
Four-inch
metal exhaust
duct is required.
Support:
The floor must be
able to support
dryer weight
of 175 pounds.
Dryer Door Clearances
Locatlon
must be large enough
to
fully open dryer door. See
back
cover of Installation Instructlons or
label on dryer rear panel for
recessed and closet requlrements.
Fire Hazard
For your safety the information
in this
manual must be followed to minimize
the risk of fire or explosion or to
prevent property damage,
personal
injury or loss of life.
- Do Not store or use gasoline or
other flammable
vapors and liquids
in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
l
Do Not try to light any appliance.
l
Do Not touch any electrical
switch; Do Not use any phone in
your building.
l
Clear the room, building or area
of all occupants.
l
Immediately
call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
l
If you cannot reach your gas
supplier, call the fire department.
- Never install dryer up against
draperies or curtains or on carpet.
- Keep any and all items from falling
or collecting
behind the dryer.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
'8"
Check code
requirements:
Some
codes llmlt or do not
permlt installation
of
clothes dryers In
garages,
closets,
mobile
homes, or
sleeping
quarters.
Contact
your local
bullding
inspector.
max.
Open dryer and
remove
llterature
and parts packages.
\
gas burner inlet
pipe connection
at rear d dryer
Level
floor:
l-inch
maximum
floor slope
under entire dryer.
Fire Hazard
lf you Install the dryer In a garage, car-port,
or areas near vehicles where fumes from
gasoline or other flammable materials may
be present, the vapors may be heavier than
air and remain near floor. Place dryer a
mlnlmum of 18 Inches above floor. Check
wlth your bulldlng Inspector regarding
requirements for thls Installation.
Failure to follow these lnstructlons could result
In fire or explosion.
Full-Wldth
Hamper Door
Extra-large
Hamper Door
(shown above)
Mobile
Home Installation
This appliance
Is sultable for moblle home
Installations. The Installation of the dryer must
conform to the Manufactured
Home Constructlon
and Safety Standard, Title 24 CFR, Part 3280 (formerly
the Federal Standard for Moblle Home Constructlon
and Safety, Title 24, HUD, Part 280).
For moblle
home use, thls appliance
MUST be
fastened
to the floor and MUST be exhausted
to the
outside.
Order Mobile
Home Installation
Kit No.
346765 from your dealer.
Kit includes
the necessary
fastening
hardware
and detailed
installation
instructlons.
Metal exhaust
system hardware
is also
available
through
your dealer.
This installation
must conform
wlth American
National
Standard,
National
Fuel Gas Code ANSI
2223.1 - latest edition,
and all local codes and
ordinances.
Tools and materials
needed for installation:
metal exhaust duct
D
n
Provide a
rlgld gas supply line to the
A
n
Check
that
dryer Is equipped
with the correct
burner for the
particular
type of
gas in the home.
will be found on
the serial/rating
plate In door well
of the appliance.
If
#c
*
I
\
Burner information
'
I,
*
this information
does not agree
with the type of
gas avallable,
see your dealer.
dryer location.
When riGd pip&-isbsed
it should
be l/2 inch IPS. When acceptable
to the gas
supplier
and local codes,
3/8-inch
approved
tubing
may be used for lengths under 20 feet.
For lengths over 20 feet, larger tubing
should be
used. Pipe-joint
compounds
resistant to the
action
of L.P. gas must be used.
shutoff valve
"open" position
E
n
The supply line shall be equlpped
with a
shutoff valve. This valve should be located
in
the same room as the dryer and should be in a
location
that allows the valve to be opened
and closed easily. Do not block access
to
shutoff valve.
B
n
TI ?is dryer is equipped
for use with
NATURAL GAS. It is designcertified
by A.G.A. for
L.P. (propane
or butane)
gases with
appropriate
conversion.
No attempt
shall be
made
to convert
the appliance
from the gas
specified
on the serial/rating
plate for use with
a different
gas without
consulting
the serving
gas supplier.
Convenlon
must be done by a
qualified servlce technlclan.
Gas converslon
klt part numbers are llsted on the gas valve
burner base.
as supply connection lor
P
n
If the dryer is installed
in a confined
area
such as a bedroom,
bathroom
or closet,
provision
must be made
for enough
air for
combustion
and ventilation.
Check
governing
codes and ordinances.
Also, check
recessed
and closet installation
instructions
section
or
label on dryer rear panel
for detailed
instructions.
C
n
The design of this dryer has been
certified
by the American
Gas Association
for
use at altitudes
up to 10,ooO feet above
sea
level at the B.T.U. rating indicated
on the
model/serial
plate.
Burner input adjustments
are not required
when the dryer is operated
up
to this elevation.
When installed
above
10,000 feet, a four
percent
(4%) reduction
of the burner B.T.U.
rating shown on the model/serial
plate is
requlred
for each
1 ,COO foot increase
in
elevation.
For assistance
when converting
to
other gas types and/or
installing
above
10,000
feet elevation,
contact
your local service
company.
duct tape
Gas supply requirements
OBSERVE ALL GOVERNING CODES AND
ORDINANCES.
G
n
If local codes
permit,
it is
recommended
that new
flexible
metal tublng,
deslgn-certified
by the
American
Gas
Association,
be used for
Fire Hazard
l
This dryer must be connected
to a
regulated gas supply. Failure to do so
could cause hlgh-pressure gas release,
resulting In a flre or exploslon.
l
Have the L.P. gas checked by a quallfled
person before lnstalllng the dryer. The L.P.
gas supply must not exceed a pressure
0r
13" water column.
l
New flexible tubing should be used.
Reusing old flexible tubing mlght result In
possible leaks or fire hazard.
Failure to follow these lnstructlons may result
In flre or explosion.
connecting
the
appliance
to the rigid gas
supply line.
(The gas pipe which extends
through the lower rear of the appliance
has
j/g-Inch
male pipe thread.)
H
1 If rigid pipe is used as a gas
supply line, a combination
of pipe
fittings must be used to obtaln
an
in-line connection
to the dryer.
Panel A