Tools Needed For Installation - Whirlpool 3395339 Installation Instructions Manual

Coin-operated stacked dryers
Table of Contents

Advertisement

Tools needed for
installation:
adjustable
wrench
level
utility knife
pliers
Phillips screwdriver
duct tape
flat-blade
screwdriver
Parts supplied for
hstallation:
2 slide protectors
8 screws
2 slide extensions
2,30-minute
cams
2 bolt and washer
2,60-minute
cams
assemblies
4,3/4"
wood screws
Parts owner must
supply:
1 control
panel lock and key
2 coin vaults and keys (E.S.D. vault must
have projecting
lock.)
2 coin-slide
mechanisms
(vertical
8)
Parts may be ordered
from
Greenwald
Industries, Inc. or
Equipment
Systems and Devices,
Inc.
l
Greenwald
Industries, Inc.
1340 Metropolitan
Avenue
Brooklyn, NY 11237
telephone
(7 18) 82 l-9000 or
toll free (800) 22 l-0982
fax no. (718) 417-7412
l
Equipment
Systems and
Devices,
Inc.
270 New Jersey Dr.
Fort Washington,
PA 19034
telephone
(2 15) 628-0860 or
toll free (800) 523-1510
fax no. (2 15) 643-4623
Gas supply
reauirements
a
Fire Hazard
l
These dryers must be connected
to a regulated
gas supply.
Failure to do so could result in high-
pressure gas release,
resulting
in a
fire or explosion.
l
Have L.P. gas checked
by a
qualified
person before
installing
the dryer. The L.P. gas supply
must
not exceed
a pressure of 13"
water column.
l
New flexible
tubing
should be
used. Reusing old, flexible
tubing
might result in possible
leaks or
fire hazard.
Failure to follow these instructions
could result in fire or explosion.
OBSERVE ALL GOVERNING
CODES
AND ORDINANCES.
A
n
This installation
must conform
with American
National
Standard,
National
Fuel Gas Code ANSI 2223. l-
latest edition",
and all local codes
and ordinances.
B
n
The desian of this drver has
been certified
bv the American
Gas
Association
for use at altitudes
up to
10,000 feet above
sea level at the
B.T.U. rating indicated
on the
model/serial
plate.
Burner input
adjustments
are not required
when
the dryer is operated
up to this
elevation.
When installed
above
10,000 feet, a
four percent
(4%) reduction
of the
burner B.T.U. rating shown on the
model/serial
plate is required
for
each
1,000 foot increase
in elevation.
For assistance
when converting
to
other gas types and/or
installing
above
10,000 feet elevation,
contact
your local service
company.
C
n
Check
that dryers are
equipped
with the correct
burner for
the particular
type of gas used.
Burner information
will be found on
the rating plate in door well of the
appliance.
If this information
does not
agree
with the type of gas available,
see your dealer.
D
n
These dryers are shipped
for
use with NATURAL GAS. They are
certified
by the American
Gas
Association
for manufactured,
mixed
and L.P. (propane
and butane)
gases
with appropriate
conversion.
No
attempt
shall be made
to convert
the
appliance
from the gas specified
on
the rating plate for use with a
different
gas without
consulting
the
serving gas supplier.
Conversion
must
be done by a qualified
service
technician.
Gas conversion
kit part
numbers
are listed on the gas valve
burner base.
E
n
Provide a rigid gas supply
line
of l/2-inch
IPS pipe to the dryer's
location.
If the total length
of the
supply line is more than 20 feet, larger
pipe will be needed.
For L.P. gas
usage, 3/8-inch,
approved
copper
tubing
may be used. Pipe-joint
compounds
suitable
for use with L.P.
gas should be used.
F
H If local codes and ordinances
permit,
it is recommended
that new
flexible
metal tubing,
design-certified
by the American
Gas Association,
be
used for connecting
the dryers to the
gas supply line. (The gas feed pipe,
which extends
through
the lower rear
of each
dryer, is provided
with 3/8-
inch male pipe thread.)
G
n
The supply line shall be
equipped
with a shutoff valve. This
valve should be located
in the same
room as the dryers and should be in a
location
that allows ease of opening
and closing.
Do Not block access to
shutoff valve.
main gas supply line, a
combination
of fittings must be
used to obtain
an in-line connection
to the dryers.
I
n
Make sure lower edges,
back
and sides of the cabinet
are free of
obstructions
to permit adequate
clearance
of air openings
for
combustion
air. See "Recessed
area
and closet installation
instructions"
for
minimum
spacing
requirements.
J
n
For ease of installation,
operating
and servicing
(if ever
needed),
adequate
space
should be
provided
around
the dryers.
K
n
A l/8-inch,
NPT plugged
tapping,
accessible
for test gauge
connection,
must be installed
immediately
upstream
of the gas
supply connector
to the dryers.
The dryers and their individual
shutoff
valves must be disconnected
from
the gas supply piping
system during
any pressure testing of that system at
test pressures in excess of l/2 psig
(3.4 kPa).
The dryers must be isolated
from the
gas supply piping
system by closing
their individual
manual
shutoff valves
during any pressure testing of the gas
supply piping
system at test pressures
equal to or less than l/2 psig
(3.4 kPa).
Page 3