12.7 Cleaning controls

Clean the control system and the joystick with a cloth
dampened with diluted detergent.
WARNING!
Ensure that the control system is turned off and
the control pod/joystick loom plug is disconnected,
(Section 5.2).
Be careful when cleaning the joystick.
Never use abrasive or spirit based cleaners

12.8 Electrical connections

When inspecting electrical connections, pay attention to
the battery connections, the connection of batteries to
power loom and plug in sockets for the joystick, control
box and any powered actuators.
NOTE: All bus connectors, (including the joystick cable),
must be secure and firmly mated together.

12.9 Main Controller access

To access the controller:
Unplug the controller loom plug, (Fig.12.12)
Remove the seat (Fig. 12.13 & Section 6.9).
Using a cross head screw driver, undo the three
screws located inside the holes in the front shroud,
(Fig.12.14).
Lift the shroud off, (Fig.12.15).
The main controller is located on the wheelchair
frame, (Fig.12.16).
WARNING!
If you are unsure about carrying out this task, ask your
authorised Sunrise Medical dealer to do it for you.