13.3
CLEARRAY® (Ultraviolet) Water Purification System
CLEARRAY Water Purification System is exclusive
technology utilizing natural ultraviolet technology to
eliminate waterborne bacteria, viruses, and algae in
portable spas. The ultraviolet light otherwise know as
UV-C or germicidal light inactivates the microorganisms
disrupting the DNA so that it cannot reproduce and is
considered lifeless. CLEARRAY is plumbed inline with your
filtration system. After the water is drawn from the pump, filter,
and heater it is then directed though the CLEARRAY system.
Water passes through an ultraviolet light energy that treats and
disinfects the water. The water is then pumped back into the
spa giving you crystal clear water instantly. The system has a
ballast that is the power supply for the purification system; it
has two LED indicator lights the green indicating incoming power flow
and the red indicating the system is properly working. CLEARRAY is
standard for all models.
Note: The CLEARRAY System only runs when the circulation pump
is running and shuts off when either jets pump is manually activated
during spa use. The system will remain off for 5 minutes after both jets
pumps time out or are manually turned off, then resume operations if the
circulation pump is programmed to run.
After a year the bulb must be replaced. If the UV timer has been
programmed correctly a message will appear on the LED display when
the time allotted has expired. In order to clear the "blb" message a new
UV bulb needs to be installed and the timer must be reset (Section 11.6,
page 32).