Setup; Ac Power; Fuse Replacement - Chauvet LEG-4500 User Manual

Legend 4500
Table of Contents

Advertisement

3. SETUP

AC Power

This fixture has an auto-switching switch-mode power supply that can accommodate a wide
range of input voltages. The only thing necessary to do before powering on the unit is to make
sure the line voltage you are applying is within the range of accepted voltages. This fixture will
accommodate between 100V and 240V AC 50-60 Hz. All fixtures must be powered directly off a
switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel is used solely for a 0% to 100% switch.
Each fixture ships with Neutrik® power input cables. Each fixture ships with a power adapter to
male Edison connector.
Warning!
All fixtures must be connected to circuits with a suitable Earth Ground.
Depending on the application, the lighting fixture may require a different connector Please refer
to the below wire color code if installing a new connector.
Wire
Brown
Blue
Green/Yellow

Fuse Replacement

With a flat-head screwdriver, unscrew the fuse holder from its housing. Remove the damaged
fuse from its holder and replace with exact same type fuse. Screw the fuse holder back in its
place and reconnect power.
The fuse is located inside
this compartment.
Remove using a flat-head
screwdriver.
Legend™ 4500 User Manual
Connection
AC Live
AC Neutral
AC Ground
Disconnect the power cord before replacing a fuse and always
replace with the same type fuse.
Connection
Pin
AC Live
1
AC Neutral
2
Ground(Earth)
3
8