Zephyr ZTO-M79S Use, Care And Installation Manual

Zephyr zto-m79s range hood - use, care and installation guide

Advertisement

Quick Links

WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS
FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE< ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVCE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions,
contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel
to prevent power from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
CAUTION
For general ventilating use only. Do not use to exhaust cigarette ashes, hazardous
or explosive materials and vapors.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking
and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b. Always turn hood ON when cooking at high heat or when flambeing food (ie:
Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe)
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate
on fan or filter.
d. Use proper pan size. Always use cookware appropriate for the size of the surface
element.
rev:0505
www.zephyronline.com

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr ZTO-M79S

  • Page 1 WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE< ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVCE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
  • Page 2 ZTO-M79S WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Installation worka nd electrical wiring must be done by qualified person (s) in accordance with all applicable codes and standards. Including fire-rated construction.
  • Page 3: Table Of Contents

    CONTENTS INSTALLATION Mount heights & clearance Ducting 1,2,3 Specifications Electrical Mounting the hood EZ Anchors Ductless Conversion Carbon Filters FEATURES & CONTROLS Touch controls & features Advance display functions Filter change indicator Filter clean indicator 8,10 MAINTENANCE Cleaning Lights replacement WARRANTY Coverage &...
  • Page 5: Installation

    INSTALLATION DUCTING WARNING: FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
  • Page 6: Ducting 1

    INSTALLATION DUCTING Crawl space Air register 6" to 3-1/4 x 10" elbow adaptor. Ductless Re-circulating option Air Diverting Kit Ductless Re-circulating option...
  • Page 7: Specifications

    INSTALLATION SPECIFICATIONS 13-3/4" 3-5/8" 8-1/2" 2" 3/4" Elec. K.O. 33.89" Wall mount bracket 7-3/4" 7" 31.1" 23.11" ELECTRICAL WARNING: All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
  • Page 8: Mounting The Hood

    INSTALLATION INSTALLATION Mounting the Range Hood 1. Mark hood center on Center hood on wall. 2. Mark and Install Wall Mount Bracket to Wall. (For hollow drywall, use E-Z Anchors, please see next page) 3. Fasten hood onto Wall Mount Bracket with screws provided.
  • Page 9: Ez Anchors

    INSTALLATION INSTALLATION EZ ANCHORS Tap EZ anchor tip into marked drywall locations, turn with screwdriver until seated flush. Note: Whenever possible, the hood should be secured to wall studs. Use EZ anchors provided only on hollow drywall applications (minimum drywall thickness ½”).
  • Page 11: Carbon Filters

    FEATURES & CONTROLS TOUCH CONTROLS & FEATURES Blower On/Off Display (Speed level, Delay Off Indicator, Filter Clean/ Change) Lights On/Off/ Hold to Dim Adjust 6 Speed Levels 15 Min Delay Off Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower starts up on speed level 3.
  • Page 12: Filter Change Indicator

    FEATURES & CONTROLS CONTROLS: FILTER CHANGE INDICATOR (Carbon Filters) Filter Change Reminder (Carbon, if fitted): When your hood is installed as a 'Purifying' (Ductless Recirculating) unit, it is fitted with a set of Carbon Filters to purify exhaust and fumes from cooking, and re-circulates the air within the home.
  • Page 13: Cleaning

    FEATURES & CONTROLS CONTROLS: FILTER CLEAN INDICATOR (Metal Filters) Filter Clean Reminder (Standard Metal Filters fitted) Whether your hood is installed as an Exhaust or Purifying unit, a set of metal filters are fitted by the factory. These Metal Filters are intended to filter out residue from cooking. It need not be replaced on a regular basis but are required to be kept clean.
  • Page 15 MAINTENANCE LIGHTS Replacing Light Bulbs CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Carefully pry trim (w/ glass) off the socket module.
  • Page 16 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows: Two Year Limited Warranty for Parts: For two years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts to replace those that failed due to manufacturing defects.