Adjustments - Exmark Ultra Vac QDS Lazer Z HP Operator's Manual

For lazer z hp series
Hide thumbs Also See for Ultra Vac QDS Lazer Z HP:
Table of Contents

Advertisement

3.6.3. Reinstall the belt guide removed in step 3.6.1.
3.6.4. Remove Discharge chute by pulling the hairpin and chute pivot pin (from the
Drive Kit installed in section 3.2).
3.6.5. Remove the Belt Cover on the right side of the deck. Install the Blower by
inserting the mounting pin into the tube welded to the rear corner of the deck.
Pivot the blower until the front pin engages the slot in the deck. Adjust the
position of the front pin if necessary to engage the slot. Use the latch to lock the
blower in this position. Adjust tension on latch to draw blower up to deck, yet
allow release by hand.
3.6.6. Pull the idler release handle and install the belt in the upper groove of the deck
sheave.
3.6.7. Install the Belt Cover using the two knobs. Install the discharge tube assembly by
slipping the upper end into the hood, then sliding the lower end over the blower
discharge opening. Use the latches to retain the lower end to the blower.
3.6.8. Follow the operation instructions in Section 4 to run the unit. Run the unit with
the blades and blower engaged for 2 minutes. Disengage the blades, shut off
the motor, and remove the key.
3.6.9. Remove the belt cover and check to make sure that the belt is riding near the
center of the flat idler on the idler arm. If the belt is not riding near the center of
the idler, remove the blower, and bend the idler arm slightly. Reinstall the blower
and belt cover and perform steps 3.6.8 and 3.6.9 again to verify belt position.

3.7 ADJUSTMENTS:

Your Ultra Vac QDS was adjusted at the factory to operate properly. However, there are
three basic adjustments that can be made, should your unit require them:
3.7.1 Arm Position: The left and right bellcrank arms control the timing of the left and
right door opening mechanisms. The ends of these arms must be positioned
equally from the upper frame tube for proper actuation. Check this distance with
the door closed. If adjustment is necessary, loosen the allen head clamping
screw on the hub of the right hand arm. Position the arms so that their ends are
the same distance from the upper frame tube. Tighten the clamping bolt to hold
them in this position. See Figure 9.
FIGURE 8