Duerkopp Adler 650-16 Service Instructions Manual page 62

Table of Contents

Advertisement

Service settings via software
Submenu
In this submenu you can define settings for thread trimming.
Figure 50: Parameters in the submenu Thread Trim
Parameters in the submenu
Thread Trim
Icon Entry
Submenu
In this submenu, you can determine the speed for certain situations.
Figure 51: Parameters in the submenu Speed
Parameters in the submenu
Speed
Icon Entry
Service Instructions 650-16 Version 00.0 - Last Updated 09/2012
Thread Trim
n
Meaning
Speed for thread trimming
Speed
Thr. Tens. Thread tension for thread
trimming
Turn Back After trimming, the machine
automatically turns back to
a position where the needle
is slightly higher.
Speed
n
n
Meaning
Maximum speed when the pedal
Speed
is fully depressed
Speed for positioning
Pos.
Speed
Soft Speed Speed for softstart stitches
N Stitches Number of softstart stitches
180
10
1
Thread Trim
Permissible value range
50 – 250
1 – 99 The bigger the value, the
shorter the thread is trimmed
0 = No automatic
1 = Automatic turn back
4000
400
500
1
Speed
Permissible value range
100 – 4000
10 – 700
10 – 1000
1 – 10
Default
value
180
10
turn back
1
Default
value
4000
400
500
1
60

Advertisement