Error Messages; Sewing Motor Controller Error Messages - DURKOPP ADLER 745-34-2 Programming Instructions Manual

Sewing unit for runstitching of piped flap and welt pocket openings and pocket corners
Hide thumbs Also See for 745-34-2:
Table of Contents

Advertisement

8.

Error messages

8.1 Sewing motor controller error messages

Error number
Error 1051
Error 1052
Error 1053
Error 1055
Error 1056
Error 1058
Error 1062
Error 1302
Error 1342
-
Error 1344
88
In the event of an error in the control system or the machine program
the error number appears in the display.
The following tables will enable the cause of the error to be identified
and remedied.
Meaning
Sewing motor timeout
- Faulty cable to the sewing motor
reference switch
- Faulty reference switch
Sewing motor excess current
- Faulty sewing motor cable
- Faulty sewing motor
- Faulty control
Too high mains voltage
Sewing motor overload
- Sewing motor blocked / seized up
- Faulty sewing motor
- Control faulty
Sewing motor overheat
- Sewing motor seized up
- Faulty sewing motor
- Faulty control
- Sewing motor speed
- Faulty sewing motor
- Failure sewing motor IDMA
Autoincrement
Sewing motor error
- Control receives no impulse from
the impulse transmitter in the motor
Sewing motor error
Internal error
Remedy
- Replace the cable
- Replace the reference switch
- Replace the sewing motor cable
- Replace the sewing motor
- Replace the control
Check the mains voltage
- Eliminate the blocking / seizing
- Replace the sewing motor
- Replace the control
- Eliminate seizing
- Replace sewing motor
Replace control
- Replace sewing motor
- Switch the machine off/on again
- Check the cable from the impulse
transmitter in the motor to the control
- Switch the machine off/on again
- Software update
- Inform the DA-Service

Hide quick links: