7.3.12
Determining the cycle time
7.3.13
Dongle-Menu
This program determines the machine's cycle time.
–
Press OK to run the test program.
The cycle time appears on the main screen.
Info line:
Reference run
–
Execute a reference run.
–
When the set sewing program has been completed the cycle time
appears in the display.
–
To leave the test program press the RST key or
switch the machine off.
The dongle is used to memorize sewing programs, sequences and
automat parameters and to transfer these data to other sewing
automats.
The transfer direction is selected with the keys "F2" and "F4".
The data transfer is started with the "F5" key.
The exact procedure is described in chapter 4 "Memory dongle".
Cycle time
71
4