DURKOPP ADLER 745-34-2 Programming Instructions Manual page 94

Sewing unit for runstitching of piped flap and welt pocket openings and pocket corners
Hide thumbs Also See for 745-34-2:
Table of Contents

Advertisement

Error number
Error 3121
Error 3210
Error 3220
Error 3500
-
3507
3520
-
3530
3540
3545
3721
3722
Info
4301
Info
4304
Error 6551
-
6554
6651
-
6653
6751
-
6761
Error 6952
Error 7200
Error 7201
Error 7202
Error 7209
Error 7210
Error 7211
Error 7215
Error 7219
Error 7260
Error 7551
-
7555
7558
7559
90
Meaning
Insufficient or missing compressed
air pressure
Thread breakage
Empty bobbin
Error Command Interpreter /
Motor synchronization
Internal error
No dongle plugged in
Wrong dongle type
Error machine head position /
AD-Converter / Processor error
Internal error
Error step motor driver
Internal error
Error in the CAN - Module
Knife-bracket unit (AC001).
No module has been recognized at
the address.
Error in the CAN - Module
Knife-bracket unit (AC001).
Power-fail.
Error in the CAN - Module
Knife-bracket unit (AC001).
Power amplifier overheating.
Error in the CAN - Module
Knife-bracket unit (AC001).
Wrong module has been recognized
at the address.
Error in the CAN - Module
Transport unit (AC101).
No module has been recognized at
the address.
Error in the CAN - Module
Transport unit (AC101).
Power-fail.
Error in the CAN - Module
Transport unit (AC101).
Output: Overload / Short circuit
Error in the CAN - Module
Transport unit (AC101).
Wrong module has been recognized
at the address.
General error in the CAN - Modules
Communication Control Panel
interface
- Internal error
Remedy
Increase the flow or stabilize the air
pressure
Re-thread the machine again
Insert full bobbin
- Switch the machine off/on again
- Software update
- Inform the DA-Service
- Switch the machine off/on again
- Software update
- Inform the DA-Service
- Switch the machine off/on again
- Software update
- Inform the DA-Service
Check cable, jumper setting, power supply
Check cable, jumper setting, power supply
Check cable, jumper setting, power supply,
motors and power amplifier.
Check jumper setting/DIP switches
Check cable, jumper setting, power supply
Check cable, jumper setting, power supply
Check the output cable / plug.
Check jumper setting/DIP switches
Check cable
- Switch the machine off/on again
- Software update
- Inform the DA-Service

Hide quick links:

Advertisement

Table of Contents
loading