TECHNICAL DATA (Main Left Oven and Main Right Oven)
Oven
dimensions
37,0 x 38,0 x 44,8 cm
HxLxP
Volume
lt. 63
Voltage and
see data plate
frequency
may be adapted for use with any type
Burners
of gas shown on the data plate.
This appliance conforms to the following
European Economic Community
directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas)
and subsequent amendments.
- 2012/19/EEC and subsequent
amendments.
Space for fixing
The cooker can be close fitted below hotplate level. This
requires a minimum distance of 600mm between cupboard
units of hotplate height.
When installing next to a tall cupboard, partition or wall, for
a minimum distance of 400mm above hotplate level, allow
a side clearance of at least 65mm.
Table 1
Burner
HOTPLATE - Semi Rapid - Front Left
HOTPLATE - Rapid - Rear Left
HOTPLATE - Wok Outer - Centre Front
HOTPLATE - Wok Inner - Centre Front
HOTPLATE - Auxiliary - Centre Rear
HOTPLATE - Double Face - Front Right
HOTPLATE - Double Face - Rear Right
GRILL
LEFT OVEN
RIGHT OVEN
Supply
Pressures
* At 15°C and 1013 mbar - dry gas
Methane
P.C.S. = 37.78 MJ/kg
WARMING DRAWER
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
The diagram below illustrates the minimum clearance
between the cooker and adjacent walls, cupboards etc.
The wall behind the cooker, 50mm below and 450mm
above, and the width of the cooker, must be a non-
combustible material such as ceramic wall tiles.
If the cooker is to be fitted close to a corner on the left hand
side, ensure that there is a clearance of at least 50mm to
allow the main oven door to open fully for when removing
oven shelves.
Cooker hoods
If a cooker hood is to be installed, refer to the cooker hood
manufacturers' instructions regarding fixing height.
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nominal
Reduced
75
1,90
100
3,00
130
4,10
35
1,00
50
1,00
-
1,50
-
1,50
-
3,90
-
2,60
-
2,60
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
Natural Gas
By-Pass
Nozzle
1/100
1/100
(mm)
(mm)
0,40
35
102 Z
0,70
44
116 Y
1,50
63
110 x 2
0,40
24
74
0,40
24
71 x
0,40
35
88 x
0,40
35
88 x
0,70
43
144
0,45
34
123
0,45
34
123
HEAT INPUT
0.15 kW
GB
Flow*
l/h
181
286
390
95
95
143
143
371
248
248
20
17
25
5