Download Print this page

Sharp AY-X09MCJ Operation Manual page 33

Split type inverter room air conditioner

Advertisement

Model of Outdoor Unit
Compressor Manufacturer/trademark
Compressor Model
Compressor Type
L.R.A. (A)
Compressor RLA(A)
Compressor Power Input(W)
Overload Protector
Throttling Method
Starting Method
Working Temp Range (℃)
Condenser
Rows-Fin Gap(mm)
Coil length (l) x height (H) x coil width (L)
Fan Motor Speed (rpm) (H/M/L)
Output of Fan Motor (W)
Air Flow Volume of Outdoor Unit
Outdoor
Fan Type-Piece
unit
Fan Diameter (mm)
Defrosting Method
Climate Type
Isolation
Moisture Protection
Permissible Excessive Operating Pressure for the Discharge
Side(MPa)
Permissible Excessive Operating Pressure for the Suction
Side(MPa)
Sound Pressure Level dB (A) (H/M/L)
Sound Power Level dB (A) (H/M/L)
Dimension (W/H/D) ( mm)
Dimension of Package (L/W/H)( mm)
Net Weight /Gross Weight (kg)
Refrigerant Charge (kg)
Liquid line diameter(mm)
Connection
Pipe
Gas line diameter(mm)
3
m
/h
- 29 -
AE-X18MCJ
SANYO
C-6RVN93H0N
Double Rotary
41
7
1610
1NT11L-3979
Capillary
capacitor
-7℃≤T≤43℃
Aluminum fin-copper tube
2-1.4
806×660×22
780/600
60W
2700
Axial fan –1
460
Auto defrost
T1
I
IP24
3.8
1.2
56/54/52
66/64/62
846X300X685
994X428X750
52/57
R410A /1.60
φ6(1/4")
φ12(1/2")

Advertisement

loading

This manual is also suitable for:

Ay-x12mcjAe-x09mcjAe-x12mcjAy-x18mcjAe-x18mcj