FLOOR UNIT

OPERATION MANUAL

HFU-09HA03/R2(DB)
HFU-12HA03/R2(DB)
HFU-18HA03/R2(DB)
Please read this operation manual before using the air conditioner.
No.00105

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HFU-09HA03/R2(DB) and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Haier HFU-09HA03/R2(DB)

  • Page 1: Operation Manual

    FLOOR UNIT OPERATION MANUAL HFU-09HA03/R2(DB) HFU-12HA03/R2(DB) HFU-18HA03/R2(DB) Please read this operation manual before using the air conditioner. No.00105...
  • Page 2 Cautions Disposal of the old air conditioner Safety Instructions and Warnings Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe.
  • Page 3 Cautions Do not obstruct or cover the ventilation 7. The appliance is not intended for use grille of the air conditoner.Do not put fingers by young children or infirm persons or any other things into the inlet/outlet and without supervision. swing louver.
  • Page 4: Safety Instruction

    Cautions Safety Instruction Please read the following Safety Instructions carefully prior to use The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation.
  • Page 5 Cautions WARNING When abnormality such as burnt-small found, Use an exclusive power source with a immediately stop the operation button and circuit breaker contact sales shop. STRICT ENFORCEMENT Connect power supply cord After installed, the unit shall be Do not use power supply cord to the outlet completely tested for electric leakage.
  • Page 6: Parts And Functions

    Parts and Functions Indoor unit 1.OUTLET 2.CONTROL PANEL 3.INLET 4.FILTER (inside) 5.OUTLET Outdoor unit HFU-09HA03/R2(DB) HFU-12HA03/R2(DB) HFU-18HA03/R2(DB) OUTLET CONNECTING PIPING AND ELECTRICAL WIRING INLET DRAIN HOSE...
  • Page 7: Air Flow Selection

    Parts and Functions CAUTION Before opening the front grille, be sure to stop the operation and turn the Receiver breaker OFF. Do not touch the metal parts on the Signals are received from the remote inside of the indoor unit, as it may result controller here.
  • Page 8 Parts and Functions Remote Controller 5. ON/OFF Used for unit start and stop. 6. SWING Used to adjust the up/down air flow direction. 7. TEMP. Used to select your desired temperature. 8. TIMER ON display 9. SLEEP display 10. FAN SPEED display Remote controller: AUTO 11.
  • Page 9 Parts and Functions Clock Set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: 1. Press CLOCK button,"AM" or "PM" flashes. 2. Press to set correct time. Each press will increase or decrease 1 min.
  • Page 10: Auto Operation

    Operation 1. Unit start Auto Operation Press ON/OFF on the indoor unit, or press ON/OFFon the remote controller, unit starts. Previous operation status appears on LED display , and set the operation mode. Remote controller 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO...
  • Page 11: Cool Operation

    Operation Cool Operation 1. Unit start Remote controller Press ON/OFF on the indoor unit, or press ON/OFFon the remote controller, unit starts. Previous operation status appears on LED display . 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO...
  • Page 12: Dry Operation

    Operation DRY Operation 1. Unit start Press ON/OFF on the indoor unit, or press ON/OFFon the remote controller, unit starts. Remote controller Previous operation status appears on LED display . 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO...
  • Page 13: Fan Operation

    Operation FAN Operation 1. Unit start Remote controller Press ON/OFF on the indoor unit, or press ON/OFFon the remote controller, unit starts. Previous operation status appears on LED display . 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO...
  • Page 14: Heat Operation

    Operation HEAT Operation 1. Unit start Press ON/OFF on the indoor unit, or press ON/OFFon the remote controller, unit starts. Previous operation status appears on LED display . Remote controller 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO...
  • Page 15: Adjusting The Air Flow Direction

    Operation Adjusting the Air Flow Direction Notes on flap angles You can adjust the air flow direction to increase your comfort When SWING is selected, the flap swinging range depends on the operation mode.(See the figure.) Adjusting the flap COOL/DRY HEAT NOTE Unless [SWING] is selected, you should set the flap at a...
  • Page 16: Sleep Operation

    Operation SLEEP Operation SLEEP operation starts SLEEP operation stops Approx. 6 hrs Before going to bed , you can simply press the 1 hr Rises 1 SLEEP button and unit will operation in SLEEP Rises 1 1 hr mode and bring you a sound sleep. Use of SLEEP function Temperature setting Unit stop...
  • Page 17: Timer On/Off Operation

    Operation Timer On/Off Operation Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode. Operation mode will be displayed on LCD Remote controller 2. Timer mode selection Press TMIER button to change TIMER mode. Every time' the button pressed, display changes as follows: Remote controller: BLANK...
  • Page 18 Operation TIMER On-Off Operation Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. Remote Controller 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK...
  • Page 19: Power/Soft Operation

    Operation POWER/SOFT Operation POWER Operation When you need rapid heating or cooling, you can use this funciton. Selecting of POWER operation Press POWER/SOFT button. Every time the button is pressed,display changes as BLANK follows: SOFT POWER Stop the display at In POWER operation status: In HEAT or COOL mode, fan speed automatically runs in HI mode for 15 min then returns to original status setting.
  • Page 20 Operation EMERGENCY OPERATION AND TEST OPERATION EMERGENCY OPERATION Carry out this operation only when the remote POWER TIMER controller is defective or lost. Unit start When the emergency operation switch is pressed, a sound you can hear, which ON/OFF means the start of this operation. Follow the requirements below.
  • Page 21: Operation Hints

    Operation hints Remote monitoring The control board of the indoor unit reserves the communication port for remote control. If you install the peripheral equipment according to the manual of the matching remote control detector, it can realize the computer management or remote monitoring of the conditioner. Please refer to the manual of the "...
  • Page 22 Maintenance Cleaning of the unit Do not clean with hot Turn off the power switch Do not touch with wet hand water or solvent Take off the air inlet grill First switch off the power supply, take off the screw cap, loosen the screw with cross screwdriver. Clean the filter Use water or vacuum cleaner to remove dust.
  • Page 23 Maintenance Maintenance at the end of application season On a fine day, unit shall be started and operate in FAN mode for about half a day unit the inside of the unit becomes thoroughly dry. Turn off the unit operation switch and power on/off. Otherwise, there will be some electricity consumption even the unit is in stop status.
  • Page 24: Trouble Shooting

    Trouble shooting Before asking for service, check the following first. Phenomenon Cause or check points The system does not restart When unit is stopped, it won't restart immediately. immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.
  • Page 25: Installation Manual Of Room Air Conditioner

    Installation Manual of Room Air Conditioner Installation of indoor unit selection of installation place Place where it is easy to route drainage pipe and outdoor piping. Place, away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evently to every corner of the room.
  • Page 26 Installation Manual of Room Air Conditioner Tool necessary 1.Screw driver Shape and description 2.Hacksaw 3.70mm dia. hole core drill 4.Spanner(dia.17,27mm) Remote controller 5.Spanner(14,17,27mm) 6.Pipe cutter Drain hose 7.Flaring tool 8.Knife Plastic cap 9.Nipper 10.Gas leakage detector Drain-elbow or soap water 11.Measuring tape 12.Reamer Self-tapping screw...
  • Page 27 Installation Manual of Room Air Conditioner 3. Piping connection Connecting method Apply refrigerant oil at half union and flare nut. To bent a pipe, give the roundness as large as possible not to crash the pipe. When connecting pipe, hold the pipe center to center then screw nut on by hand, refer to Fig. Be careful not to let foreign matters, such as sands enter the pipe.
  • Page 28 Installation Manual of Room Air Conditioner 3. Piping connection of the outdoor unit Connecting the connecting pipe and inlet and outlet liquid pipe according to the piping method Liquid Side Gas Side Purging Method:(For R410A) 6.35mm(1/4") 9.52mm(3/8") 12.7mm(1/2") Detach the service port's cap of 3-way valve, the 3-way valve 2-way valve valve rod's cap for 2-way valve and 3-way's, connect...
  • Page 29 Installation Manual of Room Air Conditioner Note: When additional refrigerant is necessary, first purge air out of connecting pipe by external gas, then drive out the excessive refrigerant by purging method.. Brand new unit is charged 80g more refrigerant than spec. This is only for first installation to purge air in the indoor unit and connecting pipe.
  • Page 30 Installation Manual of Room Air Conditioner Others 1. Power supply and there is not power plug Air conditioner must use an exclusive line(over 16A) , with this type H05RN-F/H07RN-F(mod18). the type of power supply wire is HF05VV-3G2.5mm (mod09-12). When installation air conditioner in a wet place, try to use a circuit breaker against current leakage.
  • Page 31 Haier Industrial Park, No.1 Haier Road, Qingdao, P.R.China CONFORMITÀ ALLE DIRETTIVE EUROPEE PER I MODELLI: SPECIFICHE DI SMALTIMENTO: Tutti i prodotti sono conformi alle seguenti normative europee: Il climatizzatore è contrassegnato con questo simbolo, - Direttiva 73/23/EEC Basso Voltaggio ciò significa che i prodotti elettrici ed elettronici non...
  • Page 32 Haier Industrial Park, No.1 Haier Road, Qingdao, P.R.China CONFORMIDAD EUROPEA DE LAS REGULACIONES PARA LOS MODELOS: REQUISITOS PARA LA ELIMINACIÓN: Todos los productos están en conformidad con las siguientes Normativas Su acondicionador de aire está marcado con este Europeas: símbolo. Esto significa que los productos eléctricos y - Bajo Voltaje directiva 73/23/EEC electrónicos no deben mezclarse con el resto de resi-...
  • Page 33 Haier Industrial Park, No.1 Haier Road, Qingdao, P.R.China Contains fluorinated greenhouse gases covered by the Kyoto Protocol R410A 1+2= INFORMAZIONI IMPORTANTI SUL REFRIGERANTE UTILIZZATO Questo prodotto contiene gas fluorurati ad effetto serra inclusi nel Protocollo L’etichetta compilata deve essere collocata in prossimità della portata di cari- di Kyoto.
  • Page 34 Haier Industrial Park, No.1 Haier Road, Qingdao, P.R.China Contains fluorinated greenhouse gases covered by the Kyoto Protocol R410A 1+2= INFORMACIÓN IMPORTANTE EN RELACIÓN AL REFRIGERANTE UTILIZADO Este producto contiene los gases fluorados de efecto invernadora regulados La etiqueta rellenada debe pegarse cerca de la conexión de carga del pro- por el Protocolo de Kioto.

This manual is also suitable for:

Hfu-18ha03/r2(db)Hfu-12ha03/r2(db)

Table of Contents