F - 6 4 T P B R T O U C H P AD C O N T R O L S & I N D I C AT O R S
1
LCD Window – 32 character LCD displays
system
status
messages,
descriptions, system troubles, etc.
2
STATUS Light. Lights (green) to indicate
that the system is ready for arming. If a
zone is not secured, the light will be off
and the zone will display in the window.
If a zone has been bypassed, the
STATUS light will blink while armed.
ARMED Light. Lights (red) to indicate that
3
the system is armed. If an alarm has
occurred, the ARMED LED will be
flashing.
4
Alarm Speaker – Will sound a LOUD
steady sweep tone when intrusion is
detected or a distinct pulsating tone for a
fire alarm condition.
indicate armed AWAY, and provides for
audible voice prompts.
5
STAY Button – Press once to initiate the
arm Stay sequence.
bypasses
all
interior
simultaneously to allow free movement
within the premises. Hold down for 2
seconds if all zones secure to eliminate
60-second pre-arm delay.
6
NIGHT Button – Press to arm system in
NIGHT mode when going to sleep.
System will be fully armed with all
perimeter and interior devices activated
except for the F-64TPBR Touchpad PIR.
7
BYPASS Button – Press to bypass zones.
zone
(1) Deactivates selected zones from the
system.
zone
8
MENU Button – Press to enter Function
Mode,
functions are displayed in the LCD
Window. The desired function is then
selected by pressing the YES button.
Press RESET to exit.
9
DISARM / RESET Button – Press to
silence Fire alarms, troubles and exits
Function Mode (see MENU Button).
10
YES Button – Press to select the desired
function in Function Mode (see MENU
Button, above).
Also chirps to
11
NO Button – Press to answer no to
Function Mode questions and proceed to
the next question (see MENU Button,
above).
Stay Mode
12
ENTER Button –
zones
displayed value and to move cursor to
next position.
Integral PIR – Used to detect intruders and
13
your presence near the Touchpad during
arming and disarming. Do not block.
14
FIRE Button – Press and hold down for
2 seconds to alert the Central Station of
a fire emergency.
(2) Unbypasses a bypassed
in
which
available
system
Press
to
accept
+
15
AUX Button – Press and hold down for
2 seconds to alert the Central Station of
a auxiliary emergency.
16
Police Button – Press and hold down
for 2 seconds to alert the Central Station
of a police emergency.
17
I-FOB – The I-FOB is a uniquely coded
digital key.
Insert the I-FOB into its
keyhole to disarm the system and
silence the siren in case of an alarm.
18
Slide Plate – Lift to view brief descriptions
of Touchpad buttons and procedures.
19
Bypass Icon – Appears as a reminder that
zones have been bypassed (by pressing
the BYPASS button). If it is necessary to
bypass any inoperative zones, it is
important to have the zones repaired as
soon as possible.
20
Fire Icon – Steady indicates a fire alarm
condition. Flashing indicates fire alarm
sounding.
21
Fire TBL Icon – Indicates a problem on a
fire zone is detected.
22
System TBL Icon – Indicates a trouble
condition exists on the system. Press
SILENCE to silence sounder and display
the trouble.