e) Ensure proper electrical rating in the system by checking voltage at ignition module
terminals. To avoid system malfunction, the voltage range must be within 21.6 Volts to 26.4
Volts, and correct polarity must be maintained throughout the system.
f) Test-fire the heating system by following the lighting instructions as shown below and on
heater.

4. LIGHTING INSTRUCTIONS

1. Ensure the correct voltage is supplied and gas valve is in the ON position.
2. Turn on power to heater, set thermostat (if applicable) to desired setting, the heater will light.
3. If heater does not light: Turn off power to heater, turn gas valve to OFF position.
4. Wait for five minutes and repeat steps above. If heater does not light after three attempts, call
a qualified service technician.

5. SHUT DOWN INSTRUCTIONS

a) For temporary shutdown, turn off the electrical circuit.
For complete shutdown, turn off the electrical circuit and turn gas control knob to the
b)
"OFF" position.
6. HEATER FINISH AND APPEARANCE
Exterior heater surfaces, including stainless steel components, are coated with a black high
emissive coating that helps preserve the aesthetic appearance of the heater and improves the
radiant heat output.
With extended use, the finish coat may discolor and deteriorate to some extent due to the impact
of heat and the deposit of ambient air born particles. In some environments, the stainless steel
lens cover may experience some surface oxidization and discoloration. These are normal occur-
rences caused by heat and products of combustion and in no way affect the operation and per-
formance of the heater or the manufacturer's warranty.
OCCASIONAL FINISH MAINTENANCE
Wear protective gloves, eyewear, and breathing mask. Ensure that power to the heater is discon-
nected prior to maintenance and the application of any finish coating. Use a fine steel wool to
remove blemishes or unsightly deposit, and smooth the outer surface. The heater finish coat can
be touched up using a high temperature coating such as Thurmalox Stove Paint -Flat Black-
1200°F (650°C) or similar high temperature stove paint that is compatible with the original fin-
ish. No other coating or non-high-temperature paint finish may be applied to the heater –
use of an incompatible finish coating could create a hazardous condition such as fire or
noxious fumes, damage the heater, and void the warranty.
Apply the touch up finish with the heater in its operating orientation (facing down). Ensure that
overspray does not effect the burner tile surface - insert a paper masking above the lens screen
being coated. Remove the paper masking immediately after re-finish and prior to operation of
the heater.
: