Setting Internal Jumpers - Extron electronics RGB 109xi User Manual

Dedicated computer-video interfaces with audio and adsp
Hide thumbs Also See for RGB 109xi:
Table of Contents

Advertisement

Controls and Installation, cont'd
Attach the interface to an audio system. See "Connecting
7
audio" on page 2-12.
Plug the interface into a grounded AC power source.
8
Turn on the computer, monitor, and projector (or other
9
display device).
The image from the computer should appear on the
10
projector and monitor. If it does not, double check steps
3 through 6 and make adjustments as needed.

Setting internal jumpers

The jumpers inside the interface are set at the factory for optimal
use by most systems. However, you can change a jumper
setting to meet the needs of a particular system.
Changes to internal jumper settings must be
performed by authorized service personnel only.
The user-configurable, internal jumpers control the following
functions:
J20: Sync polarity jumper — This jumper adjusts the
output sync polarity. Horizontal (H) and
Follow
Negative
vertical (V) sync output can either follow
input sync polarity, or be forced to negative.
1
• If the jumper is on pins 1 and 2, output H and V
sync polarities are forced to negative.
• If the jumper is on pins 2 and 3, output sync
polarities follow input sync polarity: The output
sync signals' polarity is the same as the input
polarity. This is the default setting.
J40: Vertical sync width jumper — This jumper adjusts the
vertical sync pulse width. Some digital display
Wide
devices have very specific requirements for
Short
incoming sync pulse width. If no picture
1
appears, the picture cuts in and out, or the
picture is scrambled, try adjusting the vertical sync
pulse width or switching from ADSP to DDSP.
• If the jumper is on pins 1 and 2, the output vertical
sync pulse will be short (narrow).
• If the jumper is on pins 2 and 3, the output vertical
sync pulse will be wide. This is the default setting.
2-6
RGB 109xi and RGB 112xi • Installation
To change the jumper settings, do the following:
1.
If the power cord is attached, remove power from the
interface by disconnecting the AC power cord from the
unit.
2.
Remove the interface cover (the top half of the enclosure),
as shown in figure 2-3. Remove the screws from the
enclosure, slide the cover slightly towards the back of the
enclosure, enough to clear the gain/peak switch, lift the
cover, and place the cover upside down next to the base of
the enclosure.
CAUTION
Do not pull on the cable that attaches the cover to
the base. Doing so could disconnect the cable from
its connectors.
CAUTION
Do not touch any switches or electronic components
inside the interface. Doing so could damage the
interface.
Slide cover back slightly,
lift straight up.
Remove (5)
screws.
Figure 2-3 — Opening the interface cover
RGB 109xi and RGB 112xi • Installation
2-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rgb 112xi

Table of Contents