CONFIGURE MAINTENANCE SETTINGS
Set software login banner
Reset the MultiSync 100 GPS Clock to factory defaults
Add an NTP or PTP license
40
–
Security: When enabled, security enforces user account settings on the;MultiSync
100; a user must have a username and password to configure the MultiSync 100.
When disabled, no username or password is required to change configuration.
3.
Click the Update icon
changed configuration to the clock.
1.
Click the Maintenance tab in the GE Config window.
2.
Click Login Banner.
3.
Enter the text you want displayed by the GE Clock Configuration Tool software on
login, and click OK.
The changed banner text is saved to the clock.
1.
Click the Maintenance tab in the GE Config window.
2.
Click Factory Reset.
3.
Click OK in the warning message window to confirm the factory reset.
Resetting to the factory defaults changes the Administrator to the default login:
User Name: admin
Password: Password
Resetting to factory defaults resets all user accounts and passwords as well as all other
configuration settings. Use with caution.
1.
Click the Maintenance tab in the GE Config window.
2.
In the License entry area, enter the valid license code and click Add License.
3.
Click the Update icon
changed configuration to the clock.
at the top of the GE Config window to save the
at the top of the GE Config window to save the
MULTISYNC 100 GPS CLOCK – INSTRUCTION MANUAL