Section 4: Programming; Program Modes; Entering And Exiting Programming Mode; Data Field Programming Mode - Honeywell ADEMCO VISTA-40 Installation And Setup Manual

2-partitioned security system
Hide thumbs Also See for ADEMCO VISTA-40:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

Program Modes

There are two programming modes for the VISTA-40.
These are the Data Field Program Mode and the #93
Menu Mode. The Data Field Program Mode is where
many system options are programmed. The #93 Menu
Mode is an interactive mode that requires a 2-line
alpha keypad (6139/6160).

Entering and Exiting Programming Mode

Enter Programming mode using either method a or b:
a.
Press both the [✳] and [#] keys at the same time
within 30 seconds after power is applied to the
control.
b.
Enter the Installer Code + [8] + [0] + [0] keys.
The factory installer code can be changed once in
the Program mode (field ✳00).
NOTE: The default for the Installer Code is 4140.

Data Field Programming Mode

In the Data Field Program Mode you may access any
field simply by entering either [✳] or [#] + the field
number:
To write or change information in a field press [✳]
+ the field number (✳03).
To read the information in a field press [#] + the
field number (#03).
When the entries for a field are completed, the keypad
beeps three times and advances to the next field.
Summary of Data Field Programming Commands
✳91
Select partition for programming partition-specific fields
✳92
Display the software revision level of the control panel
✳93
Enter Menu mode programming
✳94
Go to next page of fields
✳99
Go back to previous page of fields or exit
Programming Mode with no installer code lockout
✳98
Exit Programming Mode with Installer Code lockout
Programming
The factory-loaded defaults (✳97) enable
keypad addresses 00-03 only. A keypad set to
one of these addresses must be used to
program the system initially.
Local keypad programming can be disabled
through Compass downloading software. If
this is done, Program mode can only be
accessed via the downloading software.
Exit the Programming mode by either method a or b:
a.
Press [✳] + [9] + [8]. Exiting by this method
prevents the installer code from being used to re-
enter Programming mode. Only method "a" can be
used to re-enter Programming mode.
b.
Press [✳] + [9] + [9]. Exiting by this method
permits the installer code to be being used to re-
enter Programming mode.
Moving Between Programming Levels
The data fields are grouped into three levels (referred to
as "pages"). The first page is accessed as soon as
Programming Mode is entered.
The second and third pages of data fields are indicated
at the keypad by a 1 and 2, respectively, in front of the
2-digit field address. "ALT PROGRAM MODE" is
displayed along with a "100" or "200," indicating which
page of program fields is accessed.
To access the next level of programming fields, perform
the following steps:
Step
Action
Press ✳94.
1
2
Press [7] + [XX], where XX = the last two
digits of the program field, and make the
desired entry.
NOTES:
Press ✳94 to move to 2
nd
press ✳99 to move back to 1
Press ✳94 to move to 3
rd
✳99 to move back to 2
nd
S E C T I O N
page, (fields 1✳01 - 1✳76);
st
page.
page (fields 2✳00 - 2✳21); press
page
4
4-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents