HP B6191-90029 User Manual page 85

Ems hardware monitors
Table of Contents

Advertisement

SNMP traps
This option sends messages to applications using SNMP traps, such as Network Node Manager. See HP
OpenView Using Network Node Manager (P/N J1169-90002) for more information on configuring SNMP
traps.
The following traps are used by EMS:
EMS_ENTERPRISE_OID
EMS_NORMAL_OID
EMS_ABNORMAL_OID
EMS_REBOOT_OID
EMS_RESTART_OID
EMS_NORMAL_SEV_OID
EMS_WARNING_SEV_OID
EMS_MINOR_SEV_OID
EMS_MAJOR_SEV_OID
EMS_CRITICAL_SEV_OID
Specify the ITO message severity for both normal and abnormal events:
Critical
Major
Minor
Warning
Normal
A specified severity other than Normal is returned under the following conditions:
Certain SNMP trap monitoring requests can map directly to severity levels. For these requests, a toggle
button <Map severity from value> is displayed. If this is selected, options selected from <Severity> are
ignored.
The When value is... condition evaluates to TRUE
The When value changes condition evaluates to TRUE
To set the SNMP trap:
1. Specify the notification type from the <Notify> list.
2. Select the opcmsg ITO option from the <Notify via> list.
3. Select the severity from the <Severity> list, (Critical, Major, Minor, Warning, Normal).
TCP and UDP
This option sends TCP or UDP encoded events to the target host name and port indicated for that request.
Thus the message can be directed to a user-written socket program.
To set the TCP or UDP conditions:
1. Select the TCP or UDP option, as appropriate, from the <Notify via> list.
2. Specify the target host name and the port.
email
This option sends event notification to the specified email address
Chapter 4
"1.3.6.1.4.1.11.2.3.1.7"
"1.3.6.1.4.1.11.2.3.1.7.0.1" - Normal notification
"1.3.6.1.4.1.11.2.3.1.7.0.2" - Abnormal notification
"1.3.6.1.4.1.11.2.3.1.7.0.3" - Reboot notification
"1.3.6.1.4.1.11.2.3.1.7.0.4" - Restart notification
"1.3.6.1.4.1.11.2.3.1.7.0.5" - Problem Event w/Normal Severity notification
"1.3.6.1.4.1.11.2.3.1.7.0.6" - Problem Event w/Warning Severity notification
"1.3.6.1.4.1.11.2.3.1.7.0.7" - Problem Event w/Minor Severity notification
"1.3.6.1.4.1.11.2.3.1.7.0.8" - Problem Event w/Major Severity notification
"1.3.6.1.4.1.11.2.3.1.7.0.9" - Problem Event w/Critical Severity notification
Using the Peripheral Status Monitor
Monitoring Request Parameters
85