# EQ : event_number : severity : enable flag : suppression time : time window :
# threshold : value threshold 1 : operator 1 : operator 2 : value threshold 2
# event_number : the number of the event
# string of "OTHER" means use this entry when no other EQ entry matches
# event number
#
# severity : the severity of the event.
#CRITICAL
#SERIOUS
#MAJOR_WARNING
#MINOR_WARNING
#INFORMATION
#
# enable flag : whether the event is enabled.
#TRUE
- event is enabled
#FALSE - event is not enabled
#
# suppression time : time, in seconds, to suppress generation and trending
# for this event after generating the event.
# Valid values are:
#NOT_USED - Never suppress the event
#1 - maxint - number of seconds to suppress
#
# time window: amount of time, in seconds, event must be seen to
# qualify event.
Valid values are:
#NOT_USED - time window thresholding not used
#ANY - time window thresholding used but no time window specified
#1-maxint - time need to see threshold events to qualify
#
# threshold : number of times in time window event must be seen to qualify
# event.
Valid values are:
#1-maxint
# NOTE: to configure event to always be generated every time it is seen,
# threshold should be set to 1 and time window should be set to "ANY"
# value threshold X, operator X : value thresholds to qualify event.
# Valid values for value threshold depend on the type of value associated
# with the event.
However, predefined value of "NONE" means this value
# threshold is not used.
#NO_OP - this operator not used
# >, < , >=, <=,==, !=.
# These values are used to qualify the event using the following logic:
#
value threshold 1 operator 1 value operator 2 value threshold 2
# For example, if the value is an integer and want to qualify event if
# value is between 60 and 70, inclusive, the entry would be:
# 60 : <= : <= 70.
If the value is an integer and want to qualify event
# if value is > 70, the entry would be : NONE : NO_OP : > : 70.
#
#
# Define event
#100 to be information severity, enabled, never suppressed
# and qualified every time it occurs
EQ:100:INFORMATION:TRUE:NOT_USED: ANY:1:NONE:NO_OP:NO_OP:NONE
# Define event
#101 to be critical severity, enabled, never suppressed
# and qualified every time it occurs
EQ:101:CRITICAL:TRUE:NOT_USED:ANY:1:NONE:NO_OP:NO_OP:NONE
EQ:100072:CRITICAL:TRUE:NOT_USED: ANY :1:NONE:NO_OP:NO_OP:NONE
#
# CLCFG_VERSION is used to define the version of this file
# This information will be added to the additional event data portion
# of the event text
# CLCFG_VERSION:V.UU.FF
CLCFG_VERSION:A.01.01
EQ:103:INFORMATION:TRUE:NOT_USED:ANY:1:NONE:NO_OP:NO_OP:NONE