Physical & Capacity Specification; Job Specification Sheet - Hellenbrand WM1-16M Owner's Manual

Hellenbrand watermate-1 series water conditioning system
Table of Contents

Advertisement

*WATER TEST
_______ Hardness CaCo
_______ Iron (ppm)
_______ pH
*SIZING INFORMATION
All Water is Softened Except:
_______ Rear Hose Bib
_______ Other _________________________________________________________________________________________
The average family uses 70 gallons per person daily for all water uses in the home, about 50 gallons per person daily if hard
water can be supplied to the toilets, and about 30 gallons per person daily for hot water only.
_________ Daily Water Usage (Gallons/Person)
x _________ Family Size
= _________ Total Gallons Per Day
x _________ Grains Per Gallon of Hardness
= _________ Total Grains Per Day
*REGENERATION SETTINGS
Time Clock: Automatic Regeneration Every _______ Days Using _______ Lbs./Salt
Meter Demand: Automatic Regeneration Every _______ Gallons Using _______ Lbs./Salt
Meter Setting _______ People/_______ Hardness
*INSTALLATION DATE __________________________________ MANUFACTURE DATE__________________________________
SERIAL NUMBER ______________________________________________________________________________________________
NOTES _______________________________________________________________________________________________________
______________________________________________________________________________________________________________
______________________________________________________________________________________________________________
*To be filled in by dealer.
DEMAND
MODEL
MINERAL
LOW SALT
NAME
CU.FT.
GRAINS/LBS
WM1-16M
0.50
9,800/3.0
WM1-24M
0.75
14,700/4.5
WM1-32M
1.00
19,600/6.0
WM1-48M
1.50
29,400/9.0
WM1-64M
2.00
39,200/12.0
WM1-96M
3.00
58,800/18.0
CABINET MODELS
DEMAND
MODEL
MINERAL
LOW SALT
NAME
CU.FT.
GRAINS/LBS
WM1-16MC
0.50
WM1-24MC
0.75
14,700/4.5
WM1-32MC
1.00
19,600/6.0
1. These conditioners are designed for hardness removal.
2. Limit of 2ppm of "Ferrous Bicarbonate" iron. Add 3 grains per gallon of hardness for each ppm iron when sizing.
3. These conditioners will not purify or make your water safe to drink.
4. Water pressure must be between 25 and 120 psi.
5. Water temperature must not exceed 110ºF and the unit cannot be subject to freezing conditions.
6. Product improvements and design changes subject to change without notice.
3

JOb sPeCifiCaTiOn sheeT

(gpg)
______ Other______________________
3
______ Other______________________
______ Other______________________
_______ Front Hose Bib _______ Kitchen Cold
CaPaCiTy & PhysiCal sPeCifiCaTiOns
CAPACITY
MED. SALT
HIGH SALT
GRAINS/LBS
GRAINS/LBS
14,100/5.0
16,600/7.5
21,200/7.5
24,900/11.3
28,200/10.0
33,200/15.0
42,300/15.0
49,800/22.5
56,400/20.0
66,400/30.0
84,600/30.0
99,600/45.0
CAPACITY
MED. SALT
HIGH SALT
GRAINS/LBS
GRAINS/LBS
9,800/3.0
14,100/5.0
16,600/7.5
21,200/7.5
24,900/11.3
28,200/10.0
33,200/15.0
_______ Toilets
SERVICE
MINERAL
BRINE
FLOW RATING
TANK
TANK SIZE
GPM/PSI
(INCHES)
(INCHES)
6.1/6.8
7 x 44
18 x 33
8.4/9.7
8 x 44
18 x 33
10.0/10.7
9 x 48
18 x 33
09.7/10.3
10 x 54
18 x 40
12.0/11.6
13 x 54
18 x 40
12.0/10.6
14 x 65
18 x 40
SERVICE
MINERAL
CABINET
FLOW RATING
TANK
SIZE
GPM/PSI
(INCHES)
(WxHxD)
6.1/6.8
07 x 35
14x46x22
8.4/9.7
08 x 35
14x46x22
10.0/10.7
10 x 35
14x46x22
MODEL NO. ___________________
TIME CLK
DLFC
BLFC
INJ.
(GPM)
(GPM)
SIZE
1.2
0.25
0
WM1-16
1.5
0.50
0
WM1-24
2.0
0.50
0
WM1-32
2.4
0.50
1
WM1-48
3.5
0.50
2
WM1-64
4.0
1.0
3
WM1-96
TIME CLK
DLFC
BLFC
INJ.
(GPM)
(GPM)
SIZE
1.2
0.25
0
WM1-16C
1.5
0.50
0
WM1-24C
2.0
0.50
0
WM1-32C
MODEL
NAME
MODEL
NAME

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents