Fan replacement in a Brocade VDX 6740T and Brocade VDX 6740T-1G
3. Remove the fan assembly from the chassis by pulling the handle on the fan assembly out and
4. Install the new fan assembly in the chassis:
CAUTION
Do not force the installation. If the power supply and fan assembly does not slide in easily, ensure
that it is correctly oriented before continuing.
FIGURE 18
5. Verify that the fan status LED is steady green to indicate normal operation (refer to
44
away from the chassis.
a. Orient the new fan assembly with the captive screw on the right, as shown in
b. Gently push the fan assembly into the chassis until it is firmly seated.
If the switch is powered up, the fan will immediately power up.
c.
Using the Phillips screwdriver, secure the fan assembly to the chassis by tightening the
captive screw.
Inserting the fan assembly in the Brocade VDX 6740T and Brocade VDX 6740T-1G
If the LED is not steady green, ensure that the fan is securely installed and seated properly.
You can enter one of the following commands at the command line prompt to display fan
status:
show chassis
show environment fan
The fan status can also be viewed using the Web Tools application.
Brocade VDX 6740 Hardware Reference Manual
Figure
18.
Table
8).
53_1002829_02