In This Chapter; Configuration For The Brocade Vdx 6740 Switches - Brocade Communications Systems Brocade VDX 6740 Hardware Reference Manual

Top-of-rack, gigabit ethernet (gbe) line-rate, low latency, lossless data center bridging (dcb) switches
Table of Contents

Advertisement

Brocade VDX 6740 Configuration

In this chapter

Configuration for the Brocade VDX 6740 switches

The Brocade VDX 6740 switches can be configured in VCS™ mode, which is enabled by default.
In VCS mode, the switch is part of an Ethernet fabric involving two or more VCS-enabled switches.
VCS technology embodies the concepts of distributed intelligence and logical chassis. Distributed
intelligence means that all configuration and destination information is automatically distributed to
each member switch in the fabric. Distributed intelligence has three major characteristics:
Logical chassis means that the entire VCS fabric appears and can be managed as a single Layer 2
switch. There are three major characteristics to logical chassis:
Brocade VDX 6740 Hardware Reference Manual
53_1002829_02
Configuration for the Brocade VDX 6740 switches . . . . . . . . . . . . . . . . . . . . 13
Creating a serial connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Permanent password assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Setting the switch IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Changing the RBridge ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Changing the VCS ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Date and time on the Brocade VDX 6740 . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Network device connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Brocade inter-switch link trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Upgrading port speeds on the Brocade VDX 6740T-1G . . . . . . . . . . . . . . . . 21
The fabric is self-forming. When two VCS-enabled switches are connected, the fabric is
automatically created and the switches discover the common fabric configuration.
The fabric is masterless. No single switch stores configuration information or controls fabric
operations. Any switch can fail or be removed without causing disruptive fabric downtime or
delayed traffic.
The fabric is aware of all members, devices, and Virtual Machines (VMs). Automatic Migration
of Port Profiles (AMPP) supports VM migration to another physical server. If the VM moves, it is
automatically reconnected to all of its original resources.
Each physical switch in the fabric can be managed as if it were a blade in a chassis. When a
VCS-enabled switch is connected to the fabric, it inherits the configuration of the fabric and the
new ports become available immediately.
You can manage the entire fabric from any switch.
You can manage the edge switches in the fabric as if they were a single switch.