6. Verify that the power supply and fan assembly status LED is steady green to indicate normal

Power supply replacement in a Brocade 6740T and 6740T-1G

The Brocade VDX 6740T and Brocade VDX 6740T-1G have two power supplies, as displayed in
Figure
power supply #2 and power supply #1.
1
2
FIGURE 15
ATTENTION
Maintain all power supplies and fan assemblies in operational condition to provide redundancy.
CAUTION
Because the cooling system relies on pressurized air, do not leave any of the power supply or fan
slots empty longer than two minutes while the switch is operating. If a power supply or fan
assembly fails, leave it in the switch until it can be replaced.
CAUTION
Disassembling any part of the power supply or fan assembly voids the warranty and regulatory
certifications. There are no user-serviceable parts inside the power supply or fan assembly.
Table 7
Brocade VDX 6740 Hardware Reference Manual
53_1002829_02
Power supply replacement in a Brocade 6740T and 6740T-1G
operation.
You can refer to
Table 6
for more LED information.
You can display the power supply and fan assembly status using the following commands from
the CLI:
show system
show environment fan
show environment power
15. The Network OS identifies the power supplies from left to right on the non-port side as
Power supply #1
3
Power supply #2
Brocade VDX 6740T and Brocade VDX 6740T-1G power supplies on the non-port side
describes the power supply status LED colors, behaviors, and actions required, if any.
Captive screws
5
39