U s i n g t h e S e t b a c k Fe a t u r e
( c o n t i n u e d )
6
Use the setback temperature band screen (Screen 23) to set the amount the
return air temperature has to drop below the setpoint on Screen 10 before
the original process temperature is restored. For example, if the activate setback
temperature was 180ºF {82ºC} and the value on Screen 23 is set to 20, once the
dryer moves into setback, the actual temperature measured at the outlet of the
hopper would have to drop below 160ºF {71ºC} to restore the original process
set point.
7
When the "Setback" Feature is active, the Setback LED will be lit, and the
actual temperature on screen 5 will eventually approach the setpoint entered in
screen 11.

S e t b a c k Fe a t u r e G u i d e l i n e s

Careful selection of setpoint values in these functions is necessary for the setback
to operate properly. The following table is only a guideline of recommended
settings for these setpoints. It will be necessary for each customer to determine the
best setpoints for their application based on experience.
Normal
Drying Temp
160° F {71° C}
240° F {116° C}
300° F {149° C}
340° F {171° C}
To turn off the setback option:
1
Enter the access code 754 (see Screen 14). Then using the scroll buttons,
scroll to menu Screen 45.
2
Turn the setback function for temperature option to "Off" by pressing the
(-) key.
3
Push the scroll button to return to access code 754, then change the code to
500. Once the number has been entered push the scroll button or cycle the
power to clear the access code.
Setback Return Temp
Setback Temp
Screen #10
(Process) Screen #11
120° F {49° C}
150° F {66° C}
135° F {57° C}
180° F {82° C}
160° F {71° C}
200° F {93° C}
180° F {82° C}
220° F {104° C}
( O p t i o n a l )