Replacing The Heaters; Regeneration Heater Tube - Conair 200 User Manual

Dryer with dc-1 controls
Hide thumbs Also See for 200:
Table of Contents

Advertisement

R e p l a c i n g t h e H e a t e r s
R e g e n e r a t i o n H e a t e r Tu b e
1
Stop the dryer, disconnect the power, and follow proper lockout
procedures.
2
Open or remove the right side panel of the dryer, as viewed
from the control panel, to gain access to the regeneration heater.
Regeneration
Heater
Clamp
Insulation
Wires
Clamp
8
Connect the hose from the reactivation inlet to the top of the new
regeneration heater tube with a clamp. The heater tube wires should be at
the bottom of the heater tube when installed into the dryer.
3
Disconnect the regeneration
heater wires and high tem-
perature switch wires at the
quick disconnects near the
heater tube.
4
Remove the insulation from
the regeneration heater tube
by cutting the insulation in a
straight line from top to bot-
tom.
5
Remove the hose and clamp
at the bottom of the heater tube.
6
While supporting the heater
tube, disconnect the hose
clamp and hose from the top
of heater tube, and remove the
heater tube from the dryer.
7
Compare the markings on the
outside of the regeneration
heater tube to ensure the new
one has the same voltage and
kW ratings as the original
heater tube. This information is
on the end nearest the wires.
(continued)