C o n t r o l F u n c t i o n D e s c r i p t i o n s
S c r e e n
Screens 15-27 require access
code 754.
SCREEN 23 (Set up Screen)
Setback Temperature Band Option
20
C09
C
SCREEN 24 (Set up Screen)
Aftercooler Flow Control Enable
Option
off
C10
C
F u n c t i o n
This screen is the Setback Temperature
Band screen. This temperature is the
amount the return air out of the hopper has
to drop below the activate setback temper-
ature (Screen 10) before the original
process temperature is restored. For exam-
ple, if the activate setback temperature was
180°F {82°C} and the dryer was in set-
back. The actual temperature measured at
the outlet to the hopper which has a 20°
Setpoint (Screen 23) would have to drop
below 160°F {71°C} to restore the original
process setpoint.
This screen is the Aftercooler Flow
Control Enable screen. By pressing the (+)
or (-) keys, the setting can be changed.
With this off or disabled, the dryer will not
open the flow control valve and try to con-
trol the return air temperature. There will
also be no set point value on Menu number
3, Screen 7.