Front Panel Header; Sata 6Gb/S Connectors - Gigabyte GA-H97M-HD3 User Manual

Hide thumbs Also See for GA-H97M-HD3:
Table of Contents

Advertisement

5) SATA3 0/1/2/3/4/5 (SATA 6Gb/s Connectors)
The SATA connectors conform to SATA 6Gb/s standard and are compatible with SATA 3Gb/s and SATA
1.5Gb/s standard. Each SATA connector supports a single SATA device. The Intel
0, RAID 1, RAID 5, and RAID 10. Refer to Chapter 3, "Configuring SATA Hard Drive(s)," for instructions on
configuring a RAID array.
7
7
SATA3
5 4
3 2
1 0
1
1
6) F_PANEL (Front Panel Header)
Connect the power switch, reset switch, speaker, chassis intrusion switch/sensor and system status indicator
on the chassis to this header according to the pin assignments below. Note the positive and negative pins
before connecting the cables.
Power LED
Power Switch
Speaker
2
1
Hard Drive
Reset
Power LED
Activity LED
Switch
Chassis Intrusion
Header
• HD (Hard Drive Activity LED):
Connects to the hard drive activity LED on the chassis front panel. The LED is on when the hard drive is
reading or writing data.
• RES (Reset Switch):
Connects to the reset switch on the chassis front panel. Press the reset switch to restart the computer if
the computer freezes and fails to perform a normal restart.
• CI (Chassis Intrusion Header):
Connects to the chassis intrusion switch/sensor on the chassis that can detect if the chassis cover has
been removed. This function requires a chassis with a chassis intrusion switch/sensor.
The front panel design may differ by chassis. A front panel module mainly consists of power switch,
reset switch, power LED, hard drive activity LED, speaker and etc. When connecting your chassis
front panel module to this header, make sure the wire assignments and the pin assignments are
matched correctly.
Pin No. Definition
1
GND
2
TXP
3
TXN
4
GND
• A RAID 0 or RAID 1 configuration requires at least two hard drives.
If more than two hard drives are to be used, the total number of
hard drives must be an even number.
• A RAID 5 configuration requires at least three hard drives. (The
total number of hard drives does not have to be an even number.)
• A RAID 10 configuration requires four hard drives.
• To enable hot-plugging for the SATA ports, refer to Chapter
2, "BIOS Setup," "Peripherals\SATA Configuration," for more
information.
• PLED/PWR_LED (Power LED):
System Status LED
S0
On
S3/S4/S5
Off
• PW (Power Switch):
20
19
Connects to the power switch on the chassis front panel. You may
configure the way to turn off your system using the power switch
(refer to Chapter 2, "BIOS Setup," "Power Management," for more
information).
• SPEAK (Speaker):
Connects to the speaker on the chassis front panel. The system
reports system startup status by issuing a beep code. One single
short beep will be heard if no problem is detected at system startup.
- 14 -
Chipset supports RAID
®
Pin No. Definition
5
RXN
6
RXP
7
GND
Connects to the power status indicator
on the chassis front panel. The LED is on
when the system is operating. The LED
is off when the system is in S3/S4 sleep
state or powered off (S5).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents